400HPONGAS
26th February 2012, 11:07 AM
Mate just drove back from Perth(1200 Kilometer drive) with the battery light stuck on ,at night with spotties as well !. So I stuck on my Torque + reader and shows a consistent 12.5V charging from the altenator,with a gradually discharging main battery,down to 12.3 volts. So,after a bit of research,it was obviously the Altenator at fault ,VCR controlling.So bought a new Altenator and for good measure a new LR battery.
So did a Altenator Change ,easy as ,1.5 hrs with the right tools ,a 36mm open ende and 4lb gimpy!!!
So why did this altenator fail?
The Alternator was full of Coolant !
Some mechanic had decided to shove a Hose on so far it was clamping on the radius instead of the flat area , Look closely at photo and its obvious.
There was even Red muck,dried coolant coming out the rear of the Altenator ,no wonder it Died !New one ,14.5 start average run 13.9
https://www.aulro.com/afvb/images/imported/2012/02/183.jpg
 
Properly position Hose/clamp
https://www.aulro.com/afvb/images/imported/2012/02/184.jpg
So did a Altenator Change ,easy as ,1.5 hrs with the right tools ,a 36mm open ende and 4lb gimpy!!!
So why did this altenator fail?
The Alternator was full of Coolant !
Some mechanic had decided to shove a Hose on so far it was clamping on the radius instead of the flat area , Look closely at photo and its obvious.
There was even Red muck,dried coolant coming out the rear of the Altenator ,no wonder it Died !New one ,14.5 start average run 13.9
https://www.aulro.com/afvb/images/imported/2012/02/183.jpg
Properly position Hose/clamp
https://www.aulro.com/afvb/images/imported/2012/02/184.jpg