View Full Version : Suspenion faults with Llams
Graeme
8th April 2012, 07:23 AM
For anyone getting suspension faults only with Llams fitted, have a look at this post regarding having the loom fixed.
http://www.aulro.com/afvb/1657476-post94.html
101RRS
8th April 2012, 03:22 PM
Not got any suspension faults as yet - the only time is when I go from access to offroad +20mm in one go:o - the system runs out of puff and the raising slowly message comes up for the last couple of mm (but then according to the handbook is not a fault message but an advisory).
Graeme
8th April 2012, 05:14 PM
Any loom connection faults will occur with using just normal height and Llams off as periodic levelling will cause all circuits to be used, but may need some rough road to shake the wires.  An overheated compressor wont be cured unless its due to loss of contact on the reservoir valve circuit (which doesn't itself trigger the amber warning light) and will therefore show-up when going from access to off-road height with a cold compressor.