Log in

View Full Version : Puma Aircon Playing Up



Prop
17th March 2013, 09:17 AM
My Aircon is as the subject line says is playing up.

Every five to ten minutes the Aircon stops cooling and feels as if it has shut down.

If I turn it off for two minutes and then turn on again it starts cooling. There is mist coming from the vents just before it stops cooling. In Brisbane a black dfer can be quite hot in summer.

Anyone had the same?

Thanks

muddymech
17th March 2013, 10:13 AM
Sounds like its freezeing. Think that's the evaporator at fault.

Sue
17th March 2013, 10:22 AM
Yup.. it seems to be a common problem in some of the Puma's.. I had mine fixed under warranty a week ago and it's working fine now.

They replaced the Sensor - Temp Evaporator. (Part # LR 036309) as it was freezing after the air con was on for ten minutes or so..

This thread may have more info for you.. :)

http://www.aulro.com/afvb/90-110-130-defender-county/120506-puma-air-con-issues-4.html

nugge t
17th March 2013, 02:23 PM
Exacatly as Sue says. Mine had the mist from the vents as well. Sensor replaced and all good. Known fault so should be no problem under warranty.