Results 1 to 4 of 4

Thread: D1 Air Con Problem

  1. #1
    Join Date
    Aug 2008
    Posts
    21
    Total Downloaded
    0

    D1 Air Con Problem

    Air Con 12/96 Build 300Tdi Discovery. Was going fine icy cold and just stopped blowing cold, fan ok. compressor not seized. 30 Amp fuse blown and when replaced blew again as soon as air con switched on. Any ideas where to look. Thanks

  2. #2
    Join Date
    Oct 2008
    Location
    Moved to Mallee/ Wimmera area in 2010
    Posts
    160
    Total Downloaded
    0
    Had the fan switch shorted out on mine. Maybe check aircon switch as it may have shorted or melted the wiring.
    Where I would start now having done it once.
    Cheers

  3. #3
    Join Date
    Jan 1970
    Location
    Adelaide Hills. South Australia
    Posts
    13,349
    Total Downloaded
    0
    Electro-mechanical clutch solenoid coil shorted to earth?

  4. #4
    Join Date
    Jan 1970
    Location
    Goolwa SA - but top ender forever
    Posts
    2,515
    Total Downloaded
    0
    Check that the wire coming from the clutch at the front of the compressor hasnt rubbed through, that would be my guess as the first place to look. Otherwise it's a case of get out the multimeter and check each electrical component that it isnt shorted to earth.

    Blythe
    Last edited by blitz; 8th January 2009 at 05:48 PM. Reason: as usual bad spelling