    What would this guy be doing when things went bang, seemed to be cranking something?
    [ame=http://www.liveleak.com/view?i=634_1362679007]LiveLeak.com - There is electricity in the air[/ame]

  2. #2
    Join Date
    Aug 2006
    Location
    Melbourn(ish)
    Posts
    26,504
    Total Downloaded
    0
    Id hazard a guess at tightening up a bolt on a fairly major bus bar that then got shorted to something that it should have been well insulated from.

    Someones going to be paying for a new panel because usually when it happens you wind up with a nice crhome spray deposit all over everything.
    Dave

    "In a Landrover the other vehicle is your crumple zone."

    For spelling call Rogets, for mechanicing call me.

    Fozzy, 2.25D SIII Ex DCA Ute
    Tdi autoManual d1 (gave it to the Mupion)
    Archaeoptersix 1990 6x6 dual cab(This things staying)


    If you've benefited from one or more of my posts please remember, your taxes paid for my skill sets, I'm just trying to make sure you get your monies worth.
    If you think you're in front on the deal, pay it forwards.

  3. #3
    2stroke Guest
    He just pumped up a circuit breaker... a big one and closed it on a dead short. High fault current driven by a transformer in close proximity on a short fat set of cables made the fiery bit... Copper melts to plasma in an instant and the conductive plasma carries the arc till the breaker or any upstream protection stops it.

  4. #4
    Join Date
    Jan 1970
    Location
    Yinnar South, Vic
    Posts
    9,943
    Total Downloaded
    0
    He is "racking out" or "racking in" a HV ciruit breaker

    They rack into position and open bus shutters at the same time and the "spouts" connect to the HV bus, something has gone pair shaped there

  5. #5
    2stroke Guest
    If he had kept the front panel of the SWBD shut before closing the breaker it may have saved him a few months in hospital. Over here the new rules make you wear a cat.4 arc flash suit.

  6. #6
    Join Date
    Aug 2006
    Location
    Melbourn(ish)
    Posts
    26,504
    Total Downloaded
    0
    could he have just pulled off a magicians trick?

    watch it carefully,
    00:00 theres a bloke and a chick (or a guy who needs a diet or to take all the stuff out of his top pockets),
    00:05 she hands over something and walks off,
    00:06 he starts doing some very theatrical moving about, theres a puff of smoke and you dont see the second guy any more.
    00:17 Theres a bright flash and a heap of smoke and we dont get to see the second guy again.

    MAGIC....
    Dave

    "In a Landrover the other vehicle is your crumple zone."

    For spelling call Rogets, for mechanicing call me.

    Fozzy, 2.25D SIII Ex DCA Ute
    Tdi autoManual d1 (gave it to the Mupion)
    Archaeoptersix 1990 6x6 dual cab(This things staying)


    If you've benefited from one or more of my posts please remember, your taxes paid for my skill sets, I'm just trying to make sure you get your monies worth.
    If you think you're in front on the deal, pay it forwards.

  7. #7
    Join Date
    Jan 1970
    Location
    Yinnar South, Vic
    Posts
    9,943
    Total Downloaded
    0
    Quote Originally Posted by 2stroke View Post
    If he had kept the front panel of the SWBD shut before closing the breaker it may have saved him a few months in hospital. Over here the new rules make you wear a cat.4 arc flash suit.
    He is not switching, he is racking, usually done with the door open, CB "should" be in an open state

    The winding he is doing is not switching, it is either racking into/out off position, or winding the spring which does the switching

  8. #8
    2stroke Guest
    It is a pneumatic operated circuit breaker. you pump them up then push a button and it closes, a fairly day to day sort of thing we do. I'd suggest by the arc flash it's on a LV ciruit breaker, 2000 plus amps. We get to see these videos all the time to give us some respect for arc flash.
    edit...Maybe they are spring operated, now you mention it, I do know that you pump the lever 6 or so times and shut your eyes and push the green button... mostly without the fire.

  9. #9
    Join Date
    Jan 1970
    Location
    Yinnar South, Vic
    Posts
    9,943
    Total Downloaded
    0
    Quote Originally Posted by 2stroke View Post
    It is a pneumatic operated circuit breaker. you pump them up then push a button and it closes, a fairly day to day sort of thing we do. I'd suggest by the arc flash it's on a LV ciruit breaker, 2000 plus amps. We get to see these videos all the time to give us some respect for arc flash.
    Correct, he is not switching

    Could be an LV breaker, although 'tis a big flame ball, but if its switched on a dead short...

    Interesting scenario, be good to know more

    Used to do maintenance on SF6, air blast, oil filled breakers etc

  10. #10
    Join Date
    Oct 2009
    Location
    Cranbourne North
    Posts
    1,929
    Total Downloaded
    0
    Well one thing is fore sure. He won`t need any fibre in his diet for a while. Saw once a sparky working on a live board. There was a rail at the correct distance in front of the board to keep a clear space. Was a flash/bang and another bang. He bounced of the railing back into the board. He did not get back to work for several months.