Thread: Electricity wiring question..

  1. #21
    Join Date
    May 2006
    Location
    Woolgoolga
    Posts
    7,870
    Total Downloaded
    0
    Nearly every bath I see is installed like that.
    As for the wiring, don't like the cable running through with the gas pipe, also the one clipped so close to the edge of the stud.

  2. #22
    Join Date
    Jul 2007
    Posts
    107
    Total Downloaded
    0
    That is one method for bath install that is acceptable. Quite normal to check into the wall as they have done. As long as meets the requirements of the National Construction Code its acceptable.
    I sit my final interview to become a Registered Builder next week so I've been studying hard and am pretty up to date on standards.
    One change I would ask for is to use cement sheet behind tiles not the aquacheck plaster.
    Yes doing bathroom renos is never fun.

    If you are concerned about the builders work get the free publication from the VBA titled Standards and Tolerances, its published to help resolve disputes like these.

  3. #23
    Join Date
    Jul 2007
    Posts
    107
    Total Downloaded
    0
    Get them to put another row of noggins just above bath all around as well.

  4. #24
    DiscoMick Guest
    Reminds me of the hotel I stayed at in Yangon where the powerpoint for the hot water heater was IN the shower!

  5. #25
    JDNSW's Avatar
    JDNSW is offline RoverLord Silver Subscriber
    Join Date
    Jan 1970
    Location
    Central West NSW
    Posts
    29,536
    Total Downloaded
    0
    Quote Originally Posted by DiscoMick View Post
    Reminds me of the hotel I stayed at in Yangon where the powerpoint for the hot water heater was IN the shower!
    On my first visit to Yangon (about 35 years ago), I stayed at the Strand Hotel. A few of electrical points worth noting -

    1. The old fashioned candlestick, candle and box of matches on the bedside table paid tribute to the reliability of the electricity supply.

    2. Anyone using the hand dryer in the Men's room dimmed the lights in the whole hotel.

    3. I was fascinated by the street lighting in the road up the side of the hotel. This comprised a length of what looked like fencing wire strung across the road, to which was attached above the middle of the street about a metre of 4" x 1" timber, underneath which were screwed connectors for a 40W fluorescent tube, a ballast and a starter socket. No other housing whatever. Power was supplied by a length of thin figure eight taped to the supporting wire.

    John
    John

    JDNSW
    1986 110 County 3.9 diesel
    1970 2a 109 2.25 petrol

  6. #26
    Join Date
    May 2008
    Location
    Perth / Thornlie
    Posts
    166
    Total Downloaded
    0

    AlertMe Wiring Rules, you're all so close..

    Quote Originally Posted by Homestar View Post
    From AS/NZS3000:2007

    Clause 3.9.8.4 - Proximity to non-electrical services.

    ( B ) Gas and water services. Requirements for the separation of distributed gas and water systems from low voltage wiring systems are provided in the AS/NZS 5601 series for gas services and AS/NZS 3500 for water services.


    So, no idea, as I don't have that standard. Maybe a set of side cutters through the offending cables before they get to the site and say some local kids must have done it during the night...
    Hi all.
    Your on the right track. AS/NZS3000/2007 including amendment 1 and 2.
    m
    Minimum Standards - Wiring Rules
    Read the next para, which came in, in July 2007.
    Wiring systems shall (the word 'shall' means in the definitions clause 1.4.84A 'indicates a statement is mandatory), maintain a separation of not less than 25mm from any above ground gas and water piping.
    Underground services are covered in clause 3.11.5
    This includes around the outside, inside, roof space and within wall cavities.
    I suggest the owner act quickly to point out to the builder and the Electrical Contractor.
    If you don't get any action, call your Network Operator and advise of non compliant wiring.
    The Contractor may then have in Electrical Inspectors order written on the build.
    Hope this helps.
    Electrical Inspector - W.A.
    Grasshopper

  7. #27
    350RRC's Avatar
    350RRC is offline ForumSage Silver Subscriber
    Join Date
    Mar 2008
    Location
    Bellarine Peninsula, Brackistan
    Posts
    5,505
    Total Downloaded
    0
    Quote Originally Posted by Grasshoppr View Post
    Hi all.
    Your on the right track. AS/NZS3000/2007 including amendment 1 and 2.
    m
    Minimum Standards - Wiring Rules
    Read the next para, which came in, in July 2007.
    Wiring systems shall (the word 'shall' means in the definitions clause 1.4.84A 'indicates a statement is mandatory), maintain a separation of not less than 25mm from any above ground gas and water piping.
    Underground services are covered in clause 3.11.5
    This includes around the outside, inside, roof space and within wall cavities.
    I suggest the owner act quickly to point out to the builder and the Electrical Contractor.
    If you don't get any action, call your Network Operator and advise of non compliant wiring.
    The Contractor may then have in Electrical Inspectors order written on the build.
    Hope this helps.
    Electrical Inspector - W.A.
    Grasshopper
    And this response is why this whole site is so good. Thanks mate!
    Last edited by 350RRC; 21st January 2017 at 10:44 PM. Reason: coz

  8. #28
    350RRC's Avatar
    350RRC is offline ForumSage Silver Subscriber
    Join Date
    Mar 2008
    Location
    Bellarine Peninsula, Brackistan
    Posts
    5,505
    Total Downloaded
    0
    Quote Originally Posted by JDNSW View Post
    On my first visit to Yangon (about 35 years ago), I stayed at the Strand Hotel. A few of electrical points worth noting -

    1. The old fashioned candlestick, candle and box of matches on the bedside table paid tribute to the reliability of the electricity supply.

    2. Anyone using the hand dryer in the Men's room dimmed the lights in the whole hotel.

    3. I was fascinated by the street lighting in the road up the side of the hotel. This comprised a length of what looked like fencing wire strung across the road, to which was attached above the middle of the street about a metre of 4" x 1" timber, underneath which were screwed connectors for a 40W fluorescent tube, a ballast and a starter socket. No other housing whatever. Power was supplied by a length of thin figure eight taped to the supporting wire.

    John
    I bet it was working.

  9. #29
    Join Date
    May 2008
    Location
    Perth / Thornlie
    Posts
    166
    Total Downloaded
    0
    And those installation are around today.
    Still compliant from the rules of the day.
    But are they safe.
    Cable do have a use by date.
    Any installation with VIR cabling should be rewired.
    Grasshopper

    But on the other hand, Myself, two sons and two grandchildren are going fishing and a bit of sand dune driving tomorrow. Wish me luck on catching a feed.

  10. #30
    350RRC's Avatar
    350RRC is offline ForumSage Silver Subscriber
    Join Date
    Mar 2008
    Location
    Bellarine Peninsula, Brackistan
    Posts
    5,505
    Total Downloaded
    0
    I hear the sharks are on the bite over there.

    DL