Yes, the problem was that the Japanese health authorities badly stuffed up and didn't test the staff who were doing the cooking while the ship was under quarantine - so although passengers were confined to their rooms, the trays that the food was being delivered to their rooms on were contaminated. Incompetence, plain and simple.
I know this is a really dumb question I already regret asking, but if the submarine AC is recirculating the same air over and over, doesn't the air eventually go stale, or whatever the technical term is?
I believe they use scrubbers. Same principle as on manned space flights.
Life Support - How Submarines Work | HowStuffWorks
I found this in the info,Compressers,
" Drive, by 5 V-belts from a two-speed 4.9- to 4.1-hp electric motor, 250 (175-345) volts direct current (d.c.)."
They are Yorks running at 330RPM,R12,bloody amazing.Sould go for ever at that speed.
Use Back pressure regulators for the AC units,haven't seen one of those for a while,the young blokes wouldn't have a clue what they are.
Remember the old ice-cream/milk cabinets,with them....LP set at one pound,BPR valve at about maybe 26 or 28PSI at a guess,so the milk won't freeze.[biggrin]
I didn't realise if you go to bottom of page and click on the pages at the very bottom,there is heaps of interesting info.
And what mongrel POS they were! The only one that I ever came across was on an oil rig where they used the same compressor rack for both chiller and freezer. Far to complicated for that application, it should never have been installed. Both refrigeration and air conditioning, along with countless other systems had to be maintained by just one "electrician", and I use that description sparingly, as most of them had only been to a 1 week course before becoming "fully qualified"! [bigsad]Quote:
Use Back pressure regulators for the AC units,haven't seen one of those for a while,the young blokes wouldn't have a clue what they are.[biggrin]
Remember the old ice-cream/milk cabinets,with them....LP set at one pound,BPR valve at about maybe 26 or 28PSI at a guess,so the milk won't freeze.
Yep,same issue here,finding a good sparky that knows Refrig and Ac control wiring is almost impossible these days,the guy we used is now retired.He was brilliant.Although i did teach him a few things.[biggrin]
I didn't mind the back pressure regulators,had heaps around on ice cream/milk cabinets,doing that many we had them worked out.[biggrin]
Oh,we also had them on cabinets with a cold plate and cross fin across the top.