    Quote Originally Posted by HangOver View Post
    I'll have a look for taps and stuff tonight.

    I would feel quite happy to replace water pipes as I have done this several times in the UK with both solder and comp. fittings but anyting to do with gas for me it's hands off.

    Hard water ermm I dunno, I do know that it leaves white marks when it dries out does that mean it's hard? Or did you mean is it packing some sort of offensive weapon?
    How old is the system? id be checking that first. Then check that one of the kids hasnt turned the inlet tap down.

  2. #12
    Join Date
    Oct 2006
    Location
    kinross, Perth, WA
    Posts
    1,573
    Total Downloaded
    0
    Im glad you asked... i may be looking for a plumber to finish my kitchen off.. current one seems favourite to let me down again...

    just need gas connecting for the oven (via flexi hose) and regulator fitting etc.. and a bit of water stuff doing...

    So is there any plumbers round wa northern burbs?

    Sorry about the hijack... although its not a hijack as its on topic... :O)

    Ta

    Steve

  3. #13
    Join Date
    May 2007
    Location
    Canberra
    Posts
    753
    Total Downloaded
    0
    Quote Originally Posted by 5teve View Post
    Im glad you asked... i may be looking for a plumber to finish my kitchen off.. current one seems favourite to let me down again...

    just need gas connecting for the oven (via flexi hose) and regulator fitting etc.. and a bit of water stuff doing...

    So is there any plumbers round wa northern burbs?

    Sorry about the hijack... although its not a hijack as its on topic... :O)

    Ta

    Steve

    You cant use a flexi on a gas conection! unless its provided by the oven manufacturer.

  4. #14
    Join Date
    Oct 2006
    Location
    kinross, Perth, WA
    Posts
    1,573
    Total Downloaded
    0
    Yes its approved for an AGA flexible hose 1.2m long. Says in those or similar words on the back of the oven cant quite remember now.. (westinghouse 900mm oven)

    Thanks

    Steve

  5. #15
    Join Date
    May 2007
    Location
    Canberra
    Posts
    753
    Total Downloaded
    0
    Quote Originally Posted by 5teve View Post
    Yes its approved for an AGA flexible hose 1.2m long. Says in those or similar words on the back of the oven cant quite remember now.. (westinghouse 900mm oven)

    Thanks

    Steve
    Did the oven come with the hose? or does it just say it?

  6. #16
    Join Date
    Oct 2006
    Location
    kinross, Perth, WA
    Posts
    1,573
    Total Downloaded
    0
    no hose provided... but says it is approved for use with. i will only use a hose supplied by a gas fitter.. not got one myself.

    There is no way you could plumb this up without one.. its a freestanding 900mm stove wedged into a 905mm gap.. takes some manouvering in!

    problems?

    Thanks

    Steve

  7. #17
    Join Date
    May 2007
    Location
    Canberra
    Posts
    753
    Total Downloaded
    0
    Quote Originally Posted by 5teve View Post
    no hose provided... but says it is approved for use with. i will only use a hose supplied by a gas fitter.. not got one myself.

    There is no way you could plumb this up without one.. its a freestanding 900mm stove wedged into a 905mm gap.. takes some manouvering in!

    problems?

    Thanks

    Steve
    I dont know about WA but if the hose is not provided then you DONT use one!!!!! BUt you can get them in fairly easily just using copper.

  8. #18
    mcrover Guest
    1st question re hot water service,

    a. could be the pressure regulator that is the last valve before it goes back into the house, they get a bit clogged up with rust or that limey sort of stuff that is in hard water.

    b. you shouldnt need to touch anything gas related to fix the problem.

    c. temp mixer valve could be blocked or faulty or if there are anti hammer spools in the system, they can drop you pressure as well.

    Q, is it on all the taps or just the shower for example as it could be a dodgey tap washer on a certain tap or blocked tap spool or broken shaft on a spool.


    Question 2, Sorry 5teve, I dont know any plumbers in Perth lol

  9. #19
    Join Date
    Oct 2006
    Location
    kinross, Perth, WA
    Posts
    1,573
    Total Downloaded
    0
    WA interpretations of AS5601 is...

    A manufacturer’s installation instructions must specify the use of a flexible hose assembly for this type of
    connection. If the instructions do not specify a means of connection, the appliance must be connected with
    copper tube and the appropriate fittings.
    The only exception is for freestanding upright stoves that have a connection point at the rear of the
    appliance and do not have specific instructions or labelling prohibiting the use of flexible hoses. Clause
    5.12.1.9 of AS 5601 2004 states that a freestanding cooking appliance having an under cooker connection
    point shall not be connected to that point using a hose assembly.
    If the gas fitter or owner wants to use a hose assembly on a stove with an under cooker connection point,
    the gas fitter must extend a rigid [copper] pipe from the connection point under the cooker and up the back
    of the stove, terminating downwards. The gas connection point shall also terminate downwards. The hose
    assembly is then connected to these points hanging in a U-shape. Refer to Clause 5.12.1.8 of AS

    still doesnt clear it up for me... but seems to exclude ovens from being prohibited. as mine is a rear and just below top connection, not under oven connection

    thoughts... and i may start another thread as i have truley hijacked hangovers thread now... sorry! i was just looking for a plumbers details... honest...

    Steve

  10. #20
    Join Date
    Jan 1970
    Location
    back in the suburbs, near joondalup
    Posts
    3,438
    Total Downloaded
    0
    thanks for the suggestions I tired turning the cold water IN tap open and closed a few times but it didn't really help.

    dumb admission time:
    I turned the gas tap off by mistake in the dark and tried to relite the pilot light but the heater was in the middle of a heat cycle and gas was in abundance, BANG !

    I nearly ***** my self, if I had any hair it would have burned off. I'm OK though.

    I will be leaving the heater alone and will call a plumber if it gets anyworse.

    At least I can realise when I do something stupid and learn from it.