    Fire Extinguishers

    I have had a small fire extinguisher in the D1 for the past couple of years and because of the hot weather in Victoria at the moment I was wondering how much Temp can a small 2kg extinguisher take in the cabin. I don't know how hot it gets in there but it must be well over 50% some days and it could'nt be good for aerosols so I make sure they are kept out but the fire exy???

    What's the general consensus. Take it out unless on a trip or leave it inside all the time???

  2. #2
    Join Date
    Aug 2006
    Location
    Melbourn(ish)
    Posts
    26,503
    Total Downloaded
    0
    Ive seen them survive in storage temps over 80 degrees.

    I dont know how much hotter as the scale stopped and pegged not much further up the scale.

    as most of them are an inert propellent with a powered the temperature shouldnt be a problem unless it causes enough pressure increase to pop the safety.
    Dave

    "In a Landrover the other vehicle is your crumple zone."

    For spelling call Rogets, for mechanicing call me.

    Fozzy, 2.25D SIII Ex DCA Ute
    Tdi autoManual d1 (gave it to the Mupion)
    Archaeoptersix 1990 6x6 dual cab(This things staying)


    If you've benefited from one or more of my posts please remember, your taxes paid for my skill sets, I'm just trying to make sure you get your monies worth.
    If you think you're in front on the deal, pay it forwards.

  3. #3
    Join Date
    Jan 1970
    Location
    Down the road from Sydney
    Posts
    14,702
    Total Downloaded
    0
    if you have had it in there a couple of years have you checked that it is still in date?
    Our Land Rover does not leak oil! it just marks its territory.......




  4. #4
    Join Date
    Feb 2008
    Location
    traralgon
    Posts
    61
    Total Downloaded
    0
    Yep still in date and I usually get the fireys to check it out when they do their extinguisher check at work (when I remember to).

  5. #5
    Join Date
    Jan 1970
    Location
    Tassie/Perth
    Posts
    1,454
    Total Downloaded
    0
    Quote Originally Posted by gwebb View Post
    I have had a small fire extinguisher in the D1 for the past couple of years and because of the hot weather in Victoria at the moment I was wondering how much Temp can a small 2kg extinguisher take in the cabin. I don't know how hot it gets in there but it must be well over 50% some days and it could'nt be good for aerosols so I make sure they are kept out but the fire exy???

    What's the general consensus. Take it out unless on a trip or leave it inside all the time???

    Leave it in. I have mine constantly in both vehicles and we regularly hit temps above 40 degrees outside here and I've never had a problem.

    Cheers
    Chris

  6. #6
    Join Date
    Jan 1970
    Location
    Ferntree Gully VIC
    Posts
    10,362
    Total Downloaded
    0
    mate it will be fine as long as it still has pressure in it

    if the safety pin is still in place and it has no pressure, i'd say she's blown the safety burst disc..............
    130's rule

  7. #7
    Join Date
    Apr 2008
    Location
    Adelaide SA
    Posts
    2,517
    Total Downloaded
    0
    And don't forget to take it out of its holder every month or so, and roll it around in your hands. Turn it upside down, and then roll it between your hands on its side.

    This should be done with all DCP (Dry Chemical Powder) extinguishers to stop the power compacting into the bottom.

  8. #8
    Join Date
    Jan 1970
    Location
    Launceston, TAS
    Posts
    853
    Total Downloaded
    0
    Mine stays in, my thinking is I would rather take the chance of a mess or it not working versus it sitting at home in the shed etc when I (or someone I come across) might need it.

    Only used 1 once, that was for a fire under the bonnett of a Vitara on the side of the road.

  9. #9
    Join Date
    May 2008
    Location
    Albury Wodonga
    Posts
    816
    Total Downloaded
    0
    Just went and had a look at all 3 of my 1kg extinguishers - 2 in car, one for BBQ

    They were all pressure stamped to cope with a max 21 MPa - 3 different brands, although 2 were identical looking...

    Their standard fill is usually around 1000 kPa, or 1 MPa, and state they should be checked to 2 MPa. The short point of it all is that they should withstand huge heat and still not leak/explode. Although if you want to be silly and shoot them... anything is possible!

    I tried to find a date on them, and could only find a manufacture date on the cylinder, how long is it safe to keep them for? Or is it more a case of they should just be inspected annually and tested by suitably qualified people? I'm fairly sure the cylinders themselves are meant to be good for 10 years without inspection as per most pressurised cylinders.

    Seano

  10. #10
    Join Date
    Jan 1970
    Location
    South Yundreup,WA.
    Posts
    7,468
    Total Downloaded
    0
    They are designed to be left out in the weather, heat/cold/rain/wind etc.
    2011 Discovery 4 TDV6
    2009 DRZ400E Suzuki
    1956 & 1961 P4 Rover (project)
    1976 SS Torana (project - all cash donations or parts accepted)
    2003 WK Holden Statesman
    Departed
    2000 Defender Extreme: Shrek (but only to son)
    84 RR (Gone) 97 Tdi Disco (Gone)
    98 Ducati 900SS Gone & Missed

    Facta Non Verba

Page 1 of 2 12 LastLast

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!