2 Attachment(s)
wiring issue twin compressor
Just a heads up for those with an ARB Twin Compressor.
When I powered it up for the first time, I was looking for somewhere to cable tie the outlet (fitted to a short piece of air hose) and the outlet coupling arced out on the bracket. Took a few measurements and found I had 14V going through the airline to the fitting.[bawl] Not having time before our maiden voyage to take it back, I pulled it apart to see what was wrong; initially thinking I had squashed a wire putting it back together after rotating the outlet. Nope! Pulled the tape of the wiring loom and found a crimp joint from the control loom +ve to the first main power +ve. I got continuity from pin one on the power socket to this supposedly insulated joint by simply resting the test probe on the joints insulation tape. Not very well insulated at all. Pics below. I taped it properly and put some loom tube over the whole loom as well to protect the wiring where it is cable tied to the frame. I have sent this information to ARB head office and received a thankyou letter in response. They will follow it up for improving their product. I know a few people who have had these for years with no problem, so maybe mine was a Friday job. In any case, just though I better share this on here.
Works a treat now! [biggrin]
Attachment 122805Attachment 122806