13/02/20 First test results for the SSB HVT-50D, a 60Ah AGM.
After fully charging the SSB on the 09/02/20 and letting the battery settle overnight, on the 10/02/20, a 2.1A amp load was applied.
Attachment 157997
The battery was discharged down to 10.69v ( around 2% SoC ) and supplied a total of 68 amperes ( 68Ah ).
Attachment 157998
PLEASE NOTE, this is a 60Ah battery based on a C20 rating ( 3 amp discharge load ) but the test was conducted at a ( roughly ) C30 rating.
This is why the total discharge ampere hours was higher than the battery’s 60Ah rating.
I will continue to conduct a number of discharge tests using the 2.1 amp load and then will conduct a C20 ( 3 amp load ) test.
I installed my HVT-50D this morning. $280 landed Darwin.
I’ve been out of internet for a few weeks now. What was the result of the SSB vs Optima tests?
Are you positive about that?