    Quote Originally Posted by ian4002000 View Post
    The Ctek bluetooth battery monitors will use quite a bit of power.
    That quite interesting, and idea of their power consumption?

    I only use the BM2 Bluetooth Battery Monitors and they claim a power usage of just 1ma.

    I have not bothered to test this out.

  2. #12
    Join Date
    Dec 2011
    Location
    Adelaide
    Posts
    838
    Total Downloaded
    0
    Quote Originally Posted by drivesafe View Post
    That quite interesting, and idea of their power consumption?

    I only use the BM2 Bluetooth Battery Monitors and they claim a power usage of just 1ma.

    I have not bothered to test this out.
    Just found this but doesn't help much.

    ctek.JPG
    2012 L320 Range Rover Sport Fuji White
    REMLR 012
    No 5 Trailer ARN 177-295
    2006 Disco 3, 4L V6 Petrol SE Deceased Feb 26 2023
    SOLD Engineers Trailer - no id
    SOLD RAAF 231194 Perentie 110 GS - SIR ANGUS
    SOLD 4MP COY Series 3 FFR 30-209

  3. #13
    Join Date
    Jan 2015
    Location
    Sydney
    Posts
    885
    Total Downloaded
    0

    Disco 4 Dual battery issues - Battery drain

    Quote Originally Posted by drivesafe View Post
    That quite interesting, and idea of their power consumption?

    I only use the BM2 Bluetooth Battery Monitors and they claim a power usage of just 1ma.

    I have not bothered to test this out.
    According to Ctek specs less than 1mA @12.5V

    https://www.ctek.com/storage/BBB54B7...-low-UK-EN.pdf
    Everything is easy when someone else is doing it
    MY14 SDV6 SE Corris Grey
    Compomotive 18s : D697s : Traxide DBS : LLAMS : ARB compressor : IC-450N
    Rhino Platform : GOE compressor, Tx & front bash plates, deluxe sliders

  4. #14
    Join Date
    Apr 2012
    Location
    Whyalla, SA
    Posts
    7,064
    Total Downloaded
    0
    Quote Originally Posted by Aussie Jeepster View Post
    Just found this but doesn't help much.

    ctek.JPG
    Solves the issue... line 4 of the spec - hardly a dent.

  5. #15
    Join Date
    Oct 2017
    Location
    Trunkey Creek
    Posts
    33
    Total Downloaded
    0
    I found something on the net that said 1ah over a month.

  6. #16
    Join Date
    May 2012
    Location
    Wannanup WA
    Posts
    1,477
    Total Downloaded
    0
    I've attached a screen shot of fuses I checked yesterday to check for high current draw. Hoping I'm doing this right. I couldn't reach the lower dozen odd fuses in the bottom of the glove box because of my bad back. Also tested the ones in the engine bay. They were tested with the vehicle off, unlocked and the passenger door and bonnet opened.
    Not sure just how you are testing the fuses, but the following may help:

    https://static1.squarespace.com/static/582b77aa6a4963c3f199b0a5/t/5989d6f3d482e9b676e942b5/1502205684108/Fuse_Voltage_Drop_Chart_-_Standard_Fuse.pdf

    https://us.autologic.com/news/testing-parasitic-draw-via-fuse-voltage-drop

    You cannot be showing 10 amps across a blown fuse.



  7. #17
    Join Date
    Oct 2017
    Location
    Trunkey Creek
    Posts
    33
    Total Downloaded
    0
    Hi Old Farang.

    I wasn't showing 10amp across the old fuse.

    The fuse is a 10amp and was blown.

    The other tests show the amperage showing through the meter.

    Thanks.

  8. #18
    Join Date
    Oct 2017
    Location
    Trunkey Creek
    Posts
    33
    Total Downloaded
    0
    Is anyone on the forum able to advise if the draw through the fuses is normal please? Any advice regarding finding what's causing the batteries to go flat would be appreciated.

    Thanks.

  9. #19
    Join Date
    May 2012
    Location
    Wannanup WA
    Posts
    1,477
    Total Downloaded
    0
    Quote Originally Posted by Tommy Armstrong View Post
    Hi Old Farang.

    I wasn't showing 10amp across the old fuse.

    The fuse is a 10amp and was blown.

    The other tests show the amperage showing through the meter.

    Thanks.
    On the screen shot that you posted you have shown all the readings in mV (millivolts). To be able to read ANY current draw (amps) your test instrument HAS to be in series with whatever circuit that you are trying to read. If you read the mV "drop" ACROSS the fuse while it is still in the circuit, then you need to cross reference whatever reading that you have with the charts that I posted.

    It is possible to use a "clip on" ammeter around the wire you are trying to monitor, but it needs to be a good quality meter to accurately read milliamps.

  10. #20
    Join Date
    Aug 2015
    Location
    Notting Hill
    Posts
    62
    Total Downloaded
    0
    Quote Originally Posted by Old Farang View Post
    Not sure just how you are testing the fuses, but the following may help:

    https://static1.squarespace.com/static/582b77aa6a4963c3f199b0a5/t/5989d6f3d482e9b676e942b5/1502205684108/Fuse_Voltage_Drop_Chart_-_Standard_Fuse.pdf

    https://us.autologic.com/news/testing-parasitic-draw-via-fuse-voltage-drop

    You cannot be showing 10 amps across a blown fuse.

    Hi Old Farang,
    Thanks for the info.
    It will help me in my investigation.
    Regards
    GIL