Page 1 of 2 12 LastLast
Results 1 to 10 of 15

Thread: fluid flow through two pipes

  1. #1
    Join Date
    May 2003
    Location
    On The Road
    Posts
    30,042
    Total Downloaded
    0

    fluid flow through two pipes

    This is not a car question,, more a question on how fluids flow through pipes.
    I recently had to add T pieces to the inlet and outlet of the heater in my D2, this was to run much hotter water through the LPG regulator.
    My question is,
    how does the new T'd hose know which way to flow(though I dont think direction matters)
    and
    what happens to the volume/pressure of water from a 5/8 hose if an identical hose is run off it?
    and this might be the same question in reverse
    how does fluid from a 5/8 hose get back into a 5/8 hose already flowing/full?

    Please get as technical as you like, but words of only a couple of syllables,, ok?
    "How long since you've visited The Good Oil?"

    '93 V8 Rossi
    '97 to '07. sold.
    '01 V8 D2
    '06 to 10. written off.
    '03 4.6 V8 HSE D2a with Tornado ECM
    '10 to '21
    '16.5 RRS SDV8
    '21 to Infinity and Beyond!


    1988 Isuzu Bus. V10 15L NA Diesel
    Home is where you park it..

    [IMG][/IMG]

  2. #2
    Join Date
    Apr 2009
    Location
    Crafers West South Australia
    Posts
    11,732
    Total Downloaded
    0
    Simple really. Viscosity and velocity in a flowing fluid cause pressure differences between different points of the circuit therefore flow happens in that circuit. If water had no viscosity you would have perpetual motion. In the case of your heater circuit the heater core sets up a pressure difference between the two tees and the extra hoses simply allow more flow from the higher pressure to the lower. As soon as your water pump stops turning all flow stops as there is no longer any water velocity. That is why a loss of fan belt causes converters to ice up in short order and sometimes prevent an engine melt down.

  3. #3
    Join Date
    May 2003
    Location
    On The Road
    Posts
    30,042
    Total Downloaded
    0
    soooo--
    if the new hose has less pressure, will more water flow through it than the heater?
    "How long since you've visited The Good Oil?"

    '93 V8 Rossi
    '97 to '07. sold.
    '01 V8 D2
    '06 to 10. written off.
    '03 4.6 V8 HSE D2a with Tornado ECM
    '10 to '21
    '16.5 RRS SDV8
    '21 to Infinity and Beyond!


    1988 Isuzu Bus. V10 15L NA Diesel
    Home is where you park it..

    [IMG][/IMG]

  4. #4
    Join Date
    Apr 2009
    Location
    Crafers West South Australia
    Posts
    11,732
    Total Downloaded
    0
    Quote Originally Posted by Pedro_The_Swift View Post
    soooo--
    if the new hose has less pressure, will more water flow through it than the heater?
    I don't think you know what "pressure" means. The new pipes don't "have less pressure", they may or may not have a lower or higher pressure drop at a given flow rate. If you tested the pressure drop* as say 0.2 psi at 2 litres per second through the heater core and its pipes after the tee, and say 0.3 psi at 2 litres a second across the converter and its pipes from the tee, you would say that when connected together (ie the same pressure drop) it's likely that the converter circuit would flow less coolant than the heater. So your pressure drop in a pair of parallel circuits depends on the length of the hoses, the size of the passages in the converter or heater and any other obstruction in the hoses.

    Practically, if your converter hose circuit is 6 inches long expect more coolant to flow through the converter, if it's 6 feet long expect the heater to get more. And as I mentioned a few posts ago, I once converted a P38 and had to add a restrictor to the converter circuit as it was mounted on the drivers side right next to the heater hoses. Yours is on the opposite side and the hoses are considerably longer than those to the heater.

    I just found the picture I posted up way back in 2009



    The converter on that one is just in front of the brake unit and has short hoses.

    * To test pressure drop you could get a calibrated bucket, a garden tap and a pressure gauge at the inlet to the circuit. You'd assume zero pressure at the bucket. Nobody does so in the real world of course, this is just a thought experiment for the kiddies.

  5. #5
    Join Date
    Jan 1970
    Location
    Two Rocks WA
    Posts
    1,361
    Total Downloaded
    0
    Hi
    Why not put the convertor hoses in series with the heater hoses?
    reasons for and against?
    My gas convertor is in serires with the heater and I have never had a problem in 20 odd years with 2 Rangies and my daughters disco 1.
    Rangie classic with flapper and omvl convertor
    Brad
    Range Rovers Have Charactors inside them
    LROCWA Ex member 23 years
    1971 Series 2A
    2004 Discovery2a V8 Auto
    2003 Discovery2a TD5 Manual
    1982 4door man (sadly now gone)
    1989 Vogue auto
    2011 TDV8 Vogue
    What would life be without a Rangie?



  6. #6
    Join Date
    May 2003
    Location
    On The Road
    Posts
    30,042
    Total Downloaded
    0
    I had that brainstorm too Brad
    but the man said it put too much coolant throught the reg,, would leave deposits or something?

    I would, (now!) weigh that up against having 8 more joins in my cooling system!
    "How long since you've visited The Good Oil?"

    '93 V8 Rossi
    '97 to '07. sold.
    '01 V8 D2
    '06 to 10. written off.
    '03 4.6 V8 HSE D2a with Tornado ECM
    '10 to '21
    '16.5 RRS SDV8
    '21 to Infinity and Beyond!


    1988 Isuzu Bus. V10 15L NA Diesel
    Home is where you park it..

    [IMG][/IMG]

  7. #7
    Join Date
    Jan 1970
    Location
    St Helena,Melbourne
    Posts
    16,806
    Total Downloaded
    1.13 MB
    Quote Originally Posted by Bradtot View Post
    Hi
    Why not put the convertor hoses in series with the heater hoses?
    reasons for and against?
    My gas convertor is in serires with the heater and I have never had a problem in 20 odd years with 2 Rangies and my daughters disco 1.
    Rangie classic with flapper and omvl convertor
    Brad
    This is how i did my 2 rrc's , this makes it less likely to get an airlock and more likely to get a good flow of hot coolant thru the converter.

    Sent from my GT-I9300 using AULRO mobile app
    MY08 TDV6 SE D3- permagrin ooh yeah
    2004 Jayco Freedom tin tent
    1998 Triumph Daytona T595
    1974 VW Kombi bus
    1958 Holden FC special sedan

  8. #8
    Join Date
    Aug 2006
    Location
    Melbourn(ish)
    Posts
    26,516
    Total Downloaded
    0
    theres no simple answer to your question....

    the implied answer is run the 2 heat exhcangers in series. the sequence depends on what you're trying to achieve.

    if your heat echangers add heat to the cooling system then you put them in so the exhanger that adds the lesser amount is first in flow. IF you put it in the other way around then you may find the added heat from the first exhanger heats the coolant up to the point where the second exchanger doesnt get any heat transfer.

    IF your taking heat out I recommend putting the one in the engine bay in last as you'll pick up some heat on the exhcanger from the heat radiating off of the engine.

    if you're doing one addative and one subtractive... take your best guess. I generally route them up whichever way makes the hoses flow better.
    Dave

    "In a Landrover the other vehicle is your crumple zone."

    For spelling call Rogets, for mechanicing call me.

    Fozzy, 2.25D SIII Ex DCA Ute
    Tdi autoManual d1 (gave it to the Mupion)
    Archaeoptersix 1990 6x6 dual cab(This things staying)


    If you've benefited from one or more of my posts please remember, your taxes paid for my skill sets, I'm just trying to make sure you get your monies worth.
    If you think you're in front on the deal, pay it forwards.

  9. #9
    Join Date
    Nov 2009
    Location
    Western Victoria
    Posts
    14,101
    Total Downloaded
    0
    The correct place to place the supply "T" to the converter is between the water pump and the heater core regulating valve.
    If you connect the converter and heater core in series, when you (or the climate control) restricts hot water flow to the heater core, hot water flow to the heater converter is also restricted. This is not neccessarily what you want to achieve.

  10. #10
    Join Date
    Feb 2004
    Location
    Williams West Aust
    Posts
    20,998
    Total Downloaded
    0
    Quote Originally Posted by Mick_Marsh View Post
    The correct place to place the supply "T" to the converter is between the water pump and the heater core regulating valve.
    If you connect the converter and heater core in series, when you (or the climate control) restricts hot water flow to the heater core, hot water flow to the heater converter is also restricted. This is not neccessarily what you want to achieve.
    I was under the impression modern climate control units run hot water to the heater core 100% all the time.Blend motors control a flap that allows an amount of heated air to be drawn into the climate controled air if its required.
    Could be wrong,not often

    Andrew
    DISCOVERY IS TO BE DISOWNED
    Midlife Crisis.Im going to get stuck into mine early and ENJOY it.
    Snow White MY14 TDV6 D4
    Alotta Fagina MY14 CAT 12M Motor Grader
    2003 Stacer 525 Sea Master Sport
    I made the 1 millionth AULRO post

Page 1 of 2 12 LastLast

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!