    Fujitsu split system fault code

    One for the leccies. Hopefully someone can tell me what this fault code means. I have a Fujitsu RC split system in a bedroom that is not cooling. Model AOTR12LCC. When you start it up it functions normally for a few minutes then the outdoor unit shuts down and an error code shows up on the indoor unit. The error code is : Red operation light OFF. Green timer light flashes 3 times. From what I can find out by checking online for error codes it says "Serial signal (reverse) error in operation" What exactly does that mean to a novice like me. I was thinking it might be another "gecko" fault as we get a few of them up here on the circuit boards. Can't get a leccie to look at it for some time - any ideas?
    I have a good spare outdoor unit in the shed that I can pinch parts from if I knew what it was.
    Cheers......Brian
    1985 110 V8 County
    1998 110 Perentie GS Cargo 6X6 ARN 202516 (Brutus)

  2. #2
    Join Date
    May 2007
    Location
    in the wild New England, NSW
    Posts
    4,918
    Total Downloaded
    0
    Watching with interest Brian to see what the experts say. I just had a few of these RC type (Daikin) a/cs installed and I noted that there is a 4th "signal" wire in the flex between the units to enable communication for obvious reasons.

    FWIW I came across this: http://www.orionair.co.uk/PDF/fujits...e-shooting.pdf

    Hopefully I may learn something

    Summer is coming ...

  3. #3
    Bearman's Avatar
    Bearman is offline TopicToaster Gold Subscriber
    Join Date
    Jun 2006
    Location
    Hay Point
    Posts
    4,042
    Total Downloaded
    0
    Well, seeing as I didn't get any replies I went ahead and changed the circuit board out for a good one I had on another unit and "bingo" it is working perfectly. It would appear that the code is for "stuffed PCB" Hahaha!!
    Cheers......Brian
    1985 110 V8 County
    1998 110 Perentie GS Cargo 6X6 ARN 202516 (Brutus)

  4. #4
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,641
    Total Downloaded
    0
    Well often if the PCB is stuffed it can’t give you the correct code anyway.

    You did well.

    Oh,and by the way you need a fully qualified AC mechanic,not a “leccie” to look at it.

    Sorry we don’t do enough of those domestic Fujitsu units to know the codes off the top of my head.

    Apart from Daikin, as the bigger units have same/similar codes to the smaller units,and we do a lot of them.
    Paul

    D2,D2,D2a,D4,'09 Defender 110(sons), all moved on.

    '56 S1,been in the family since...'56
    Comes out of hibernation every few months for a run

  5. #5
    Join Date
    Aug 2006
    Location
    Gold Coast QLD
    Posts
    1,747
    Total Downloaded
    0
    Also, after using a Fridgie and not a sparkie, put some Vicks vapourub around the PCB on the metal surface, Gecko's cant stand the stuff and it lasts for years. Its a good thing to use around the alarm sensors in the office too. stops errant alarm calls at 3am
    1964, S2a SWB "Ralph"
    1977, S3 SWB "Smeg" (Gone)
    1996 D1 300tdi auto (Gone)
    1973 Rangie Classic (Gone)
    2012, 110 (Series 12) Puma "The Tardis"
    1962 109" Tray Back "Ernie"
    1998 D1 300tdi (Dizzy)
    2017 Kawasaki Versys 1000

    You must now cut down the tallest tree in the forest... With... A HERRING!!!!!

Tags for this Thread

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!