If it was a long time since the old blend motors failed, the flaps themselves could have become stuck due to non use over an extended period of time, although if they were working fine prior to the failure of the old belnd motors, they might be ok.
Have you tried the ac to see if cold air comes out?
Sometimes the book symbol will not appear for a while even if there is a fault.
I'm assuming the fans are working and the wiring is correct for the new motors.
I would check hevac fuses 8 & 17 as a starting point, they can cause these issues.
If that makes no difference, I'd also check the heater core and hoses to make sure there is not a blockage somewhere.
I would disconnect the heater hoses in the engine bay and give it a flush out with a hose just to make sure that is not the issue.
Even though the heater core is hot, a partial blockage could affect things.
Let me know how that goes!
Cheers, Pete.