    Help with voltage regulator terminals

    I have been wrestling with a new wiring loom for a 88” 2a.
    Of course there are no notes with the loom - and I have just come up with my first query.
    The wiring diagram in the manuals have the following identifications on the regulator.

    However the new regulator (same as my old one) is labelled as this -

    I have looked around and can’t seem to find a translation. Does anyone have one handy?

  2. #2
    Join Date
    Dec 2010
    Location
    Mirboo North Victoria
    Posts
    430
    Total Downloaded
    0

    Regulator

    7Just had a quick look at your regulator from what I see
    E earth
    D dynamo output
    Wl warning light/ generator run light
    F generator field
    B battery and ammeter
    To check warning light operation connect a power source to the wire, using a power source with a fuse inline, this will prevent damage if the circuit is wrong.The light light should go out on the dash if you have the correct wire.
    A1 should be from ignition switch to regulator in the old system and warning light
    A ammeter
    I have included a wiring circuit to cross reference it may help it is from Lucas wiring training course.
    http://www.rjh-heritage.ch/index_htm...%20Service.pdf
    The second is from the Dynamo and Regulator testing document which has your new regulator in it.
    Testing a Tractor Dynamo and Regulator

    Hope this helps Gippy

  3. #3
    JDNSW's Avatar
    JDNSW is offline RoverLord Silver Subscriber
    Join Date
    Jan 1970
    Location
    Central West NSW
    Posts
    28,805
    Total Downloaded
    0
    The regulator you show is not the original, presumably been replaced some time in the past. Do you still have the original generator?

    I am pretty certain you need to connect the wires intended for both A and A1 to B on the regulator. Other connections are the same.
    John

    JDNSW
    1986 110 County 3.9 diesel
    1970 2a 109 2.25 petrol

  4. #4
    Join Date
    Feb 2018
    Location
    East Gippsland
    Posts
    131
    Total Downloaded
    0
    Thanks Guys
    I’ll carefully go through the advice and see where I end up.

  5. #5
    Join Date
    Feb 2018
    Location
    East Gippsland
    Posts
    131
    Total Downloaded
    0
    Sorry I missed the question - yes I still have the original genny. It seems that it worked fine before -
    So I’ll work it out again I guess.

  6. #6
    Join Date
    Feb 2018
    Location
    East Gippsland
    Posts
    131
    Total Downloaded
    0
    Gippy - those links you included are GOLD. Thanks

Tags for this Thread

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!