Originally Posted by
PeterJ
I fitted the whole system myself, 300Ah LiFeP04 battery (with BMS), Victron Energy Multiplus 3000w inverter/charger [fully programmable with dedicated voltage sensing, I can not understate how important dedicated voltage sense is] Victron Energy 100/50 solar controller, [again fully programmable] 840w solar panels [simply] and VE battery monitor, most importantly a programmable low voltage cut off protection for the battery from Intervolt. You must not rely on the battery management system cut off to provide a low voltage safety cut off point for the system, it's only there as a OMG panic stations savior.
I can be using the microwave or coffee machine (a George job) the inverter is pulling 120 to 130A, turn on the van water pump, TV, lights whatever and not so much as a micro hiccup. I do not charge from the D4, absolutely no need.
Peter