3rd March 2006, 01:21 PM
#21
Sorry no photos!!!
You can do the job yourself but you must have the a/c evacuated and then regased when you put it back in.You will see what you have to do when you pull it out in to the open it was surely a poor design.Hope i am of some help next time i will take photos.
-
3rd March 2006, 10:09 PM
#22
One of the main causes of the problem is the two a/c drains going into one pipe through the floor. get rid of the t/piece,drill new holes in the floor directly under drains and run new pipes out the floor and the water will get out of the catch tray. I have done this a number of time in the shop and it works.
Good luck.
-
5th March 2006, 04:12 PM
#23
Originally posted by DH
One of the main causes of the problem is the two a/c drains going into one pipe through the floor. get rid of the t/piece,drill new holes in the floor directly under drains and run new pipes out the floor and the water will get out of the catch tray. I have done this a number of time in the shop and it works.
Good luck.
Excellent! I'll do that and let everyone know!
Cheers
Chris