Under the trans tunnel, have alook up with a torch from underneath you will see two rubber drain pipes, one either side of the g'box. They protrude through the floor about 40mm. They get blocked easily, just pull the inner sleeve out, (you'll get wet no doubt) the one with the cone shaped end that slips inside the outer bit, and wash all the leaf litter and mud etc out of it. Sticking it back in is optional, I tend to think leaving them out in the tropics is a good thing due to the volume of water cascading out of the evaporator on any given day!!!
JC


Reply With Quote
Are you saying that a tube can be further extracted out of that, Justin?
with a hole in the end of the short rubber tube coming through the floor. I leave the cones out on some as they continually block up over winter, come summer = wet floor