Page 2 of 2 FirstFirst 12
Results 11 to 17 of 17

Thread: Blowing the fuse when I select reverse??

  1. #11
    Join Date
    Jul 2012
    Location
    ferntree gully australia
    Posts
    1,408
    Total Downloaded
    0
    Quote Originally Posted by rick130 View Post
    Ditto, constant although intermittent issue, did as you did and haven't had a problem (touch wood) in five or so years now.
    Hi Rick ,interesting, do you know why, by pulling the cables out of the chasey fixed your problem . Was there a bare part of a wire that was no longer touching stoped the short , or could it have been something else kind regards jimr1 ...

  2. #12
    Join Date
    Jul 2008
    Location
    Lismore NSW
    Posts
    149
    Total Downloaded
    0
    Reckon mine was shorting at front where harness bends back inside chassis, - cann't confirm without removing harness, it was an intermittent fault. I was at the point of running a new wire when I accidentally fixed mine

    Brett

    110 300 tdi

  3. #13
    Join Date
    Jan 1970
    Location
    NSW far north coast
    Posts
    17,285
    Total Downloaded
    0
    Quote Originally Posted by jimr1 View Post
    Hi Rick ,interesting, do you know why, by pulling the cables out of the chasey fixed your problem . Was there a bare part of a wire that was no longer touching stoped the short , or could it have been something else kind regards jimr1 ...
    Quote Originally Posted by bcj View Post
    Reckon mine was shorting at front where harness bends back inside chassis, - cann't confirm without removing harness, it was an intermittent fault. I was at the point of running a new wire when I accidentally fixed mine

    Brett

    110 300 tdi

    What Brett said ;

  4. #14
    Join Date
    Oct 2007
    Location
    Wantabadgery, N.S.W.
    Posts
    2,742
    Total Downloaded
    0
    Given this seems to be a problem with 300TDI's, would it be possible to shove a length of that electrical concertina insulation stuff that's split up the side, in over that length of the loom. I've never seen it out so don't know if it'd work.
    Don.

  5. #15
    Join Date
    Sep 2007
    Location
    Aussie Expat in NZ
    Posts
    3,451
    Total Downloaded
    0

    Blowing the fuse when I select reverse??

    Quote Originally Posted by nod 130 View Post
    Given this seems to be a problem with 300TDI's, would it be possible to shove a length of that electrical concertina insulation stuff that's split up the side, in over that length of the loom. I've never seen it out so don't know if it'd work.
    Don.
    Yes, but it will become difficult after a metre or so. I run conduit over my whole loom but fitted it with the loom out of the LR. If you ft the split stuff, run a few raps of electrical tape over the section where you are sliding the conduit on as the shard edges can damage the cable. (I found anyway).

    The flexible conduit is cheap and will safe lots of grief over time.
    Hercules: 1986 110 Isuzu 3.9 (4BD1-T)
    Brutus: 1969 109 ExMil 2a FFT (loved and lost)

  6. #16
    Join Date
    Sep 2007
    Location
    Aussie Expat in NZ
    Posts
    3,451
    Total Downloaded
    0

    Blowing the fuse when I select reverse??

    Also, you can't slid it over the end as there are splits and joins that wont fit through the conduit.
    Hercules: 1986 110 Isuzu 3.9 (4BD1-T)
    Brutus: 1969 109 ExMil 2a FFT (loved and lost)

  7. #17
    Join Date
    Jun 2007
    Location
    Margaret River
    Posts
    800
    Total Downloaded
    0
    I noticed on my 2012 130 Defender the loom runs in split tube on the outside of the frame. My old 97 is inside the frame and thats where it shorted.

    Im dont know if the designers are solving a problem of shorting inside the frame or opting for a cheaper easier build?

Page 2 of 2 FirstFirst 12