 Originally Posted by 
130HCPU
					 
				 
				A/C fan recently made a noise like a leaf being sucked in and broken up.  After a short time a high pitched whistle started.  Working on the leaf theory I though that this would eventually get blown away but no such luck.  Whistle continues and gets higher in pitch with the faster fan speed.
Before I attempt to pull the fan out and check what is going on, I would appreciate any advice about possible cause, problem or fix.
Great forums by the way, only a recent member but have picked up lots of excellent information
			
		 
	 
 I assume it is a Td5 or Tdi? If so, remove the LH guard cover for the heater inlet air, ondo the screws holding the duct inplace, remove the washer bottle etc and mounting clamp and the duct can be removed completely. The heater blower fan is then right there in front of you and you will hopefully be able to see the errant leaf, or dessicated mouse with its tail stuck in the fan
(Edit: Ooops, just read it was the A/C fan, sorry different proceedure. Drop the bottom cover plate and then lower the A/C evaporator assembly down from under the dash enough to expose the fan inlet 'cage' looking thingys(there is one at each end of the fan housing) it should then become easy to again see the dessicated mouse from the fan blades.)
JC
				
			 
			
		 
			
			
			
				
					Last edited by justinc; 20th December 2009 at 09:15 AM.
				
				
					Reason: Didn't read the original post properly...
				
			
			
			
				
			
			
				The Isuzu 110. Solid and as dependable as a rock, coming soon with auto box😊
The Range Rover L322 4.4.TTDV8 ....probably won't bother with the remap..😈
			
			
		 
	
Bookmarks