    Quote Originally Posted by Blknight.aus View Post
    if you can get a clean one....

    put an lpg tank horizontally on the roof.

    set it up like a convection tank with your coil of copper or mains rated poly pipe.

    Feed the cold water in at the bottom and the hot water out at the top of the tank.

    Or just install a solar hot water system.
    Half the fun is the thinking, debating the pro's and con's of such a thing and then if able to build it, doing it.
    The thing I dont want to get away from is mains pressure (town supply with good pressure), So without some type of valving to stop the mains pressure backfeeding into a low pressure reticulation system I think I would blow something up.
    cheers
    blaze
    ps
    thanks for imput and ideas thus far
    cheers
    blaze

  2. #12
    Join Date
    Jan 1970
    Location
    Manly QLD
    Posts
    1,452
    Total Downloaded
    0
    My Dad has a Solahart and there is a mod that may interest you is, the HWS is a thermo siphon unit with the tank above the panels. He has put a tee on both the lines between the tank and the panels and run a ½ inch copper pipe around the chimney for the fireplace just under ceiling height.. This line thermo siphens just like the panels when the fire is going so on a cold and rainy day (like today) his solahart is boiling, and it’s so simple.
    L322 3.6TDv8 Lux

  3. #13
    Join Date
    Apr 2009
    Location
    Vic
    Posts
    342
    Total Downloaded
    0
    Many years ago on a farm we lived on we had the hot water going through the combustion stove in winter and a gal pipe grid on the roof in summer.

    It was switched over with a 3 way ball valve located at the side of the electric hot water/storage unit.

    The water used to get so hot in both winter and summer that you could make a cup of coffee straight out of the tap.

    I cant remember specifics as I was only a kid but I know it worked and we rarely ran the electric element.

    My Dad used to switch it onto boost every now and then when the fire was warming up just to make sure it worked properly.

  4. #14
    Join Date
    May 2003
    Location
    On The Road
    Posts
    30,030
    Total Downloaded
    0
    reported.
    "How long since you've visited The Good Oil?"

    '93 V8 Rossi
    '97 to '07. sold.
    '01 V8 D2
    '06 to 10. written off.
    '03 4.6 V8 HSE D2a with Tornado ECM
    '10 to '21
    '16.5 RRS SDV8
    '21 to Infinity and Beyond!


    1988 Isuzu Bus. V10 15L NA Diesel
    Home is where you park it..

    [IMG][/IMG]

  5. #15
    Join Date
    Jan 1970
    Location
    sydney
    Posts
    693
    Total Downloaded
    0
    beat me to it

Page 2 of 2 FirstFirst 12

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!