The Bosch module will happily run the OEM ignition coil off the '95 system. The Bosch module can be mounted to the same heat sink the Lucas module sits on, you will need a couple of 3mm screws and nuts to hold it on. I did one a couple of days ago on a '94 RRC 3.9, it runs perfectly.
Module replacement thread here.
Should end up wired like this:
![]()


Reply With Quote