 Originally Posted by 
ashhhhh
					
				 
				Its generally considered bad practice to solder o2 sensor connections.
I would buy new ones with the connector attached if I were you. I got mine from Amazon for $45 each.
Your symptom of one bank showing no activity is exactly what I struck with mine.
I had;
P1000 = LAMBDA SENSOR UPSTREAM
CATALYST BANK 2 DRIVE CYCLE C
OCCURED 7 TIMES
SIGNAL INVALID
FAULT IS CURRENTLY PRESENT
FAULT DETERMINED AS INTERMITTENT
FAULT DOES NOT CAUSE THE
MIL LAMP ACTIVATION
---
P0175 = MIXTURE ADAPTION FACTOR
FRA BANK 2 DRIVE CYCLE C
OCCURED 1 TIMES
SIGNAL TOO HIGH
FAULT IS CURRENTLY PRESENT
FAULT DETERMINED AS PERSISTENT
FAULT DOES NOT CAUSE THE
MIL LAMP ACTIVATION
I replaced o2 sensors, MAF, checked wiring etc.
It turned out to be caused by an air leak at the inlet manifold joint, probably injector o-rings too.
Sorted all that, no more issues.
			
		 
	