    Hi all,
    I am after some advice about my kitchen domestic fridge
    It keeps freezing up in the fridge cabinet.
    I swapped out the thermostat with a genuine replacement but no improvement
    It just doesn't seem to stop cycling, just gets colder and colder, opened it this morning and the inside was -4 degrees :x
    My lettuce was frozen
    Anyhoo, any knowledgeable guys have any suggestions?
    Yes, if interested I can give model no and such but didn't want to bore everyone with my tale of woe!

    Regards
    Ralph

  2. #2
    Join Date
    Jan 1970
    Location
    SAFETY BEACH Victoria
    Posts
    648
    Total Downloaded
    0
    1.turn the temperature knob to the min setting you may have installed it upside down .

    2 check if you have a relay turning the compressor on it my need replacing


    3 if above is not working for you call the manufacture and ask for help

  3. #3
    Join Date
    Jan 1970
    Location
    Nedlands, WA
    Posts
    2,012
    Total Downloaded
    0
    Check at the back of the fridge that the dangly part of the thermostat thingy is not touching the cabinet.

  4. #4
    Join Date
    Jan 1970
    Location
    Brissy! No flannos here!
    Posts
    8,814
    Total Downloaded
    0
    Yeh,
    Thanks Kai.
    Was gunna rip the back off as soon as I get time and look for the exact same relay :wink:
    Regards
    Roger

  5. #5
    Join Date
    Jan 1970
    Location
    2780
    Posts
    8,257
    Total Downloaded
    0
    Had the same problem on my F&P last week. Frost free no longer. Repair guy came replaced heater element and one of the fans. All better now.

    Cheers
    Simon

  6. #6
    Join Date
    Jan 1970
    Location
    NSW far north coast
    Posts
    17,285
    Total Downloaded
    0
    ok, first Q, frost free or cyclic defrost ??

  7. #7
    Join Date
    Jan 1970
    Location
    Goolwa SA - but top ender forever
    Posts
    2,515
    Total Downloaded
    0
    without having a look which is a bit hard over the internet.

    when you replaced the thermostat the probe is usually is attached to the evaporator. if for some reason it is not touching (normally there is a small clamp of some sort there) then the thermsotat is not getting the signal that the fridge is cold enough, hence it keeps running.

    That is one option the other is as stated above the the new thermostat may work backwards to the old one, so you may have it turned to it's coldest setting instead of warmer.

    Is the fridge a cyclic style? because if it has an internal defrost timer, that could also be buggered and it just keeps running.

    If that doesn't fix it then you would have to give me the model and make so I could have a quick look at the wiring diagram of one for you.

    cheers Blythe

  8. #8
    Join Date
    Jan 1970
    Location
    Brissy! No flannos here!
    Posts
    8,814
    Total Downloaded
    0
    Thanks all,
    It is a Frigidaire 410litre upside down jobbie.
    Model number FB410F-01 with 'cyclamatic defrost' 8O

    It is beginning to sh*t me. Thawed lettuce on my lunch is horrid.
    On the w/e it gets pulled apart and if it is a really good fridge that can be fixed, it will go back together :roll:

    Regards
    Ralph

  9. #9
    Join Date
    Jan 1970
    Location
    NSW far north coast
    Posts
    17,285
    Total Downloaded
    0
    OK, it's a cyclic defrost.

    First up, when the evaporator (the plate in the back of the frig) is frosted/iced, does the ice pattern go all the way across the plate, or is there only partial coverage ?
    To really check, do the old lick the finger test and see if it sticks all the way across the evaporator.
    If this works all the way, the refrigerant charge is probably OK.
    If not, there is a shortage of refrigerant. What happens here is that the part of the evaporator the t/stat feeler bulb touches doesn't get cold enough to cycle the compressor off, causing the frig to run too cold and freezing everything inside.

  10. #10
    Join Date
    Jan 1970
    Location
    Brissy! No flannos here!
    Posts
    8,814
    Total Downloaded
    0
    Thanks so far,
    Yes the frost line seems to be ok, the evaporator gets nicely frosty all the way across and up.

    It also defrosts nicely as well so I assume the heater / defrost cycle is ok.
    I fiddled with the thermostat capillary tube again last night, ensureing it was touching the evaporator as the recess it sits into is a fairly loose fit.
    I then thought bugger it, lets see what this baby can do

    So I set it to max on the dial and left it for a few hours. Got down to - 8 but then....when I backed off the knob and turned it to low again, the compressor stopped, so that is encouraging

    mmmmmm