    Diagnosing air suspension problem

    Is anyone familiar enough wit the air suspension system to assist with diagnosis of the following problem?
    In the mornings the suspension light comes on immediately if a height change is attempted. If left alone the compressor will run for a couple of minutes and when you move off a fault will usually be logged. This has been occurring since before we left on our trip but prior to leaving no faults were permanently logged. I suspect I have a slow leak that is emptying the tank but don't know where to start looking. Do the lines to the compressor stay at tank pressure or is there another valve? Once the vehicle is running everything goes normally Any suggestions welcome
    Regards
    Tote
    Go home, your igloo is on fire....
    2014 Chile Red L494 RRS Autobiography Supercharged
    MY2016 Aintree Green Defender 130 Cab Chassis
    1957 Series 1 107 ute - In pieces
    1974 F250 Highboy - Very rusty project

    Assorted Falcons and Jeeps.....

  2. #2
    Join Date
    Mar 2008
    Location
    Sydney, Australia
    Posts
    2,351
    Total Downloaded
    0
    Check the dryer to see if the desicant is damp and has expnaded?

  3. #3
    Join Date
    Sep 2008
    Location
    Up a hill in the deer park
    Posts
    662
    Total Downloaded
    0
    +1 on that .

    If you've got a fault code reader , check pump vacuum fault.

  4. #4
    Join Date
    Jan 1970
    Location
    NSW SW Slopes
    Posts
    12,030
    Total Downloaded
    0
    Quote Originally Posted by Tote View Post
    Do the lines to the compressor stay at tank pressure or is there another valve?
    The pressure in the lines from the compressor to the reservoir valve and the front and rear valve blocks is always dumped as soon as the compressor is stopped, excepting if the exhaust valve is siezed shut!

    The compressor should not run for so long. Most likely the vehicle is too slow to raise which causes a fault to be logged.

    As well as a possible clogged dryer, the compressor outlet valve could be worn-out, so hopefully its either this or the dryer rather than the compressor itself. With the dryer removed from the compressor, you should be able to blow through the dryer albeit with some resistance. The dessicant can be removed from the dryer and dried in a micro-wave oven. New dryers are available, as well as outlet valves for at least some versions of the compressor.
    MY21.5 L405 D350 Vogue SE with 19s. Produce LLAMS for LR/RR, Jeep GC/Dodge Ram
    VK2HFG and APRS W1 digi, RTK base station using LoRa

  5. #5
    Join Date
    Jan 1970
    Location
    NSW SW Slopes
    Posts
    12,030
    Total Downloaded
    0
    Quote Originally Posted by Neil P View Post
    check pump vacuum fault.
    Pressure?
    MY21.5 L405 D350 Vogue SE with 19s. Produce LLAMS for LR/RR, Jeep GC/Dodge Ram
    VK2HFG and APRS W1 digi, RTK base station using LoRa

  6. #6
    Join Date
    Mar 2008
    Location
    Sydney, Australia
    Posts
    2,351
    Total Downloaded
    0
    Yup drier is easy to fix. remove compressor and remove drier. Then empty contents into abowl and microwave till dry. Reasemble and it should work.
    Just did mine. Now goes up quick and farts properly.

  7. #7
    Join Date
    Feb 2007
    Location
    Yass NSW
    Posts
    5,599
    Total Downloaded
    0
    Ok, an update. I fitted a spare compressor that I had put a new exhaust valve in with no real difference in the fault displayed. A couple of observations:
    The compressor I pulled out is the current part number and less that 12 months old
    The spare compressor is an older one but is noticably quieter running.

    I am still experiencing the same symptoms where I will get a couple of suspension faults in the morning and then the vehicle will work fine all day. The number of faults is intermittant and occasionally will occur in the afternoon if parked all day and sometimes I wont get a fault at all that day.

    Vehicle is not dropping overnight

    When I replaced the compressor after the vehicle had been sitting for a while the hose that connects to the blue connector on the drier was slightly pressurised. I would have thought the pressure would have been vented from this line when the compressor shut down.

    BBYER, can you please repost those links on the schematics from the UK forum as I couldnt find them with a search before you posted them.

    Regards,
    Tote
    Go home, your igloo is on fire....
    2014 Chile Red L494 RRS Autobiography Supercharged
    MY2016 Aintree Green Defender 130 Cab Chassis
    1957 Series 1 107 ute - In pieces
    1974 F250 Highboy - Very rusty project

    Assorted Falcons and Jeeps.....

  8. #8
    Join Date
    Jan 1970
    Location
    NSW SW Slopes
    Posts
    12,030
    Total Downloaded
    0
    The noisier compressor is probably the better one but suggests a blocked dryer. Have you removed its dryer and tried to blow through it?
    MY21.5 L405 D350 Vogue SE with 19s. Produce LLAMS for LR/RR, Jeep GC/Dodge Ram
    VK2HFG and APRS W1 digi, RTK base station using LoRa

  9. #9
    Join Date
    Feb 2007
    Location
    Yass NSW
    Posts
    5,599
    Total Downloaded
    0
    Yep, both driers are easy to blow through with only a small amount of resistance.
    Regards,
    Tote
    Go home, your igloo is on fire....
    2014 Chile Red L494 RRS Autobiography Supercharged
    MY2016 Aintree Green Defender 130 Cab Chassis
    1957 Series 1 107 ute - In pieces
    1974 F250 Highboy - Very rusty project

    Assorted Falcons and Jeeps.....

  10. #10
    Join Date
    Jan 1970
    Location
    NSW SW Slopes
    Posts
    12,030
    Total Downloaded
    0
    It sounds like it may be time to find out what the codes are indicating in case there's something a bit unusual. Mine got to be slow to rise some time after a new compressor was fitted and it wasn't until I spotted then fixed a reservoir valve error that proper operation was restored.
    MY21.5 L405 D350 Vogue SE with 19s. Produce LLAMS for LR/RR, Jeep GC/Dodge Ram
    VK2HFG and APRS W1 digi, RTK base station using LoRa

Page 1 of 2 12 LastLast

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!