    TDV6 injector leak off pipe O-ring replacement

    I have a problem with a fuel leak on a diesel Territory, it's from one of the injector leak off connections. Diesel leaks down onto the manifold causing a lot of smoke !!

    Crazy money for a set of leak off pipes/connections so I'm hoping it's just an O-ring failed.

    Has anyone had to do this on a Discovery and could maybe tell me the O-ring size. Looks like a fun job removing the cable tray to hopefully get to the injector !
    Lets hope it's just an O-ring problem.



    Colin
    '56 Series 1 with homemade welder
    '65 Series IIa Dormobile
    '70 SIIa GS
    '76 SIII 88" (Isuzu C240)
    '81 SIII FFR
    '95 Defender Tanami
    Motorcycles :-
    Vincent Rapide, Panther M100, Norton BIG4, Electra & Navigator, Matchless G80C, Suzuki SV650

  2. #2
    Join Date
    Jan 1970
    Location
    St Helena,Melbourne
    Posts
    16,770
    Total Downloaded
    1.13 MB
    Not a difficult job really just need to be careful of the clips, I would just get an oring kit and match them.
    MY08 TDV6 SE D3- permagrin ooh yeah
    2004 Jayco Freedom tin tent
    1998 Triumph Daytona T595
    1974 VW Kombi bus
    1958 Holden FC special sedan

  3. #3
    Join Date
    Apr 2016
    Location
    Melbourne
    Posts
    4,517
    Total Downloaded
    0
    I used Diesel Systems in Cheltenham to redo the fragile plastic leak off connectors on the Pug Hdi a while back. While they didn't specifically list the parts for the Puegeot, Ford parts are same, and in effect mine were just Bosch type fittings(as opposed to Seimens in some instances).

    Took some samples and they matched them up. Helpful people.

    I can't remember the prices of each bit and piece, got brass fittings and seals(plus a couple of spare seals) and hose to make it all up, IIRC less then $100 all up for a 4cyl.

    Hope that helps.
    Arthur.

    All these discos are giving me a heart attack!

    '99 D1 300Tdi Auto ( now sold :( )
    '03 D2 Td5 Auto
    '03 D2a Td5 Auto

  4. #4
    Join Date
    Jan 1970
    Location
    Narre Warren South
    Posts
    6,796
    Total Downloaded
    0
    Quote Originally Posted by loanrangie View Post
    Not a difficult job really just need to be careful of the clips, I would just get an oring kit and match them.
    Getting the cable tray out was 'interesting'.
    Removed a couple of the injector plugs, cut cable ties, after several attempts used brute force and the plastic survived. Worked out a way of re-installing without too much need for more brute force.

    The O-ring was badly twisted and broke on removal. Material is blue so possibly Flourosilicon which has good temperature resistance.
    Recently had problems sourcing O-rings for a Coleman stove, it used one Viton and one Flourosilicon. Local O-ring supplier couldn't help with Flourosilicon.

    Hunted through O-rings in stock, found one that fitted but cord diameter too big, found another that fitted with a stretch, I could feel a resistance when the connector was plugged back in so NBR fitted for the time being. I'll take samples to the O-ring supplier I use and try to get a match in Viton.

    The problem connector was the rearmost one so very little room to work, dropped the retaining clip once and luckily used a magnet to retrieve it. Found it best to part install the clip before plugging in the spill line connector then push the clip home.

    Onto more household chores now, maybe some time tomorrow to work on projects......


    Colin
    '56 Series 1 with homemade welder
    '65 Series IIa Dormobile
    '70 SIIa GS
    '76 SIII 88" (Isuzu C240)
    '81 SIII FFR
    '95 Defender Tanami
    Motorcycles :-
    Vincent Rapide, Panther M100, Norton BIG4, Electra & Navigator, Matchless G80C, Suzuki SV650

  5. #5
    Join Date
    Jan 1970
    Location
    Narre Warren South
    Posts
    6,796
    Total Downloaded
    0
    Quote Originally Posted by AK83 View Post
    I used Diesel Systems in Cheltenham to redo the fragile plastic leak off connectors on the Pug Hdi a while back. While they didn't specifically list the parts for the Puegeot, Ford parts are same, and in effect mine were just Bosch type fittings(as opposed to Seimens in some instances).
    Thanks,
    I might give them a try for the correct O-rings.

    Colin
    '56 Series 1 with homemade welder
    '65 Series IIa Dormobile
    '70 SIIa GS
    '76 SIII 88" (Isuzu C240)
    '81 SIII FFR
    '95 Defender Tanami
    Motorcycles :-
    Vincent Rapide, Panther M100, Norton BIG4, Electra & Navigator, Matchless G80C, Suzuki SV650

  6. #6
    Join Date
    Jan 1970
    Location
    Narre Warren South
    Posts
    6,796
    Total Downloaded
    0
    LR part number is LR019118.
    The NBR O-ring is holding up, local supplier thinks the original is Viton (they did a hardness test).

    Colin
    '56 Series 1 with homemade welder
    '65 Series IIa Dormobile
    '70 SIIa GS
    '76 SIII 88" (Isuzu C240)
    '81 SIII FFR
    '95 Defender Tanami
    Motorcycles :-
    Vincent Rapide, Panther M100, Norton BIG4, Electra & Navigator, Matchless G80C, Suzuki SV650

  7. #7
    Join Date
    Jul 2024
    Location
    Lara
    Posts
    1
    Total Downloaded
    0
    Quote Originally Posted by gromit View Post
    Getting the cable tray out was 'interesting'.
    Removed a couple of the injector plugs, cut cable ties, after several attempts used brute force and the plastic survived. Worked out a way of re-installing without too much need for more brute force.

    The O-ring was badly twisted and broke on removal. Material is blue so possibly Flourosilicon which has good temperature resistance.
    Recently had problems sourcing O-rings for a Coleman stove, it used one Viton and one Flourosilicon. Local O-ring supplier couldn't help with Flourosilicon.

    Hunted through O-rings in stock, found one that fitted but cord diameter too big, found another that fitted with a stretch, I could feel a resistance when the connector was plugged back in so NBR fitted for the time being. I'll take samples to the O-ring supplier I use and try to get a match in Viton.

    The problem connector was the rearmost one so very little room to work, dropped the retaining clip once and luckily used a magnet to retrieve it. Found it best to part install the clip before plugging in the spill line connector then push the clip home.

    Onto more household chores now, maybe some time tomorrow to work on projects......


    Colin
    How did you put the retaining clip back on. Driving me crazy.

  8. #8
    Join Date
    Jan 1970
    Location
    Narre Warren South
    Posts
    6,796
    Total Downloaded
    0
    Quote Originally Posted by Cjross1983 View Post
    How did you put the retaining clip back on. Driving me crazy.
    From memory part install the clip, push home when fitted.
    The NBR O-ring is still holding up.

    Colin
    '56 Series 1 with homemade welder
    '65 Series IIa Dormobile
    '70 SIIa GS
    '76 SIII 88" (Isuzu C240)
    '81 SIII FFR
    '95 Defender Tanami
    Motorcycles :-
    Vincent Rapide, Panther M100, Norton BIG4, Electra & Navigator, Matchless G80C, Suzuki SV650

  9. #9
    Join Date
    Jul 2009
    Location
    Mid North Coast, NSW
    Posts
    1,093
    Total Downloaded
    51.4 KB

Tags for this Thread

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!