 Originally Posted by 
PhilipA
					
				 
				It sounds like you may also have an issue with the fans or the fan circuit.
 
First place a multimeter on the power side of the fan switch . You should have 12V. If you have 12v , then bridge the switch. If the fans do not work you need new fans or the earth from the fans is crook. If the fans work by bridging the switch the switch is crook.
 
If no 12v then work back through the relay and fuse to find the open circuit.
Without looking at the circuit, there must be 2 power feeds, one through the thermo switch for overheat and one through the aircon switch. Try the overheat circuit first as it will tell you whether its fans or power.
OK I looked at the circuit. there are two separate relays, the aircon/heating relay, and a specific relay for  the fans. the fans share earth with the compressor clutch, so if the clutch works then the fans earth should be OK , but check anyway.
To check the fans  you can also just hot wire them from the battery with a length of wire.
Regard s Philip A
			
		 
	 
 Thanks Philip - I'll check the overheat circuit 1st as I know the aircon is crook.  Think I'll get on and order a Rave CD for this as the Haynes manual isn't so clever with wiring diagrams.
I did try a hot wire from the battery (+ve and -ve wires) and neither fan worked, so it looks like several issues which is why I've been pulling my hair out.  It's nice to know that I'm on the right track though.
				
			 
			
		 
			
				
			
			