    A solar company has told me I can connect up to 2.4 kW of panels to my 2 kW (Eversolar) inverter.

    If that correct? Will it shorten the inverter life?

  2. #2
    Join Date
    Aug 2007
    Location
    Gosnells
    Posts
    6,148
    Total Downloaded
    0
    Will an engine have a shorter life if you run it j-u-s-t under the red line, with the occasional step over, - or on top of the Green, with the occasional visit near the red line???

    If you have cheap or middle-of-the-road panels, then MAX output will only occur if they're at right angles to the sun's angle and when the sun is happiest...

    If you have 'better' panels, they could go over their rated output under good - not perfect- conditions, as mine occasionally do...

    Heat kills any electronic gizmo, and running close to red-line is going to shorten the Mean Time Before Failure.

    Then there's the method the manufacturer uses to rate his inverters...

  3. #3
    Join Date
    May 2006
    Location
    Woolgoolga
    Posts
    7,870
    Total Downloaded
    0
    Ben, there will be no real dramas, when the system is pumping it will lose the top few percent of the input, but when its at say its usual 75%, you will get a greater input than you did before. Voltage and current inputs apply though as they will increase.

  4. #4
    Join Date
    Jan 1970
    Location
    Yinnar South, Vic
    Posts
    9,943
    Total Downloaded
    0
    Quote Originally Posted by superquag View Post
    Will an engine have a shorter life if you run it j-u-s-t under the red line, with the occasional step over, - or on top of the Green, with the occasional visit near the red line???

    If you have cheap or middle-of-the-road panels, then MAX output will only occur if they're at right angles to the sun's angle and when the sun is happiest...

    If you have 'better' panels, they could go over their rated output under good - not perfect- conditions, as mine occasionally do...

    Heat kills any electronic gizmo, and running close to red-line is going to shorten the Mean Time Before Failure.

    Then there's the method the manufacturer uses to rate his inverters...
    Good inverter manufacturers allow a fair percentage of overclocking, it merely clips the excess in peak periods

    Inverters are better off driven at the higher range

    So yes, perfectly fine, staying within current limits is not as critical, but within voc considering minimum temp, azimuth angle are quite crucial to inverter lifespan

    I'm about to put 4.5kw of panels on a 4kw inverter tomorrow, the design program is actually more favourable of this than 4.5 on a 5

  5. #5
    Join Date
    Apr 2009
    Location
    Crafers West South Australia
    Posts
    11,732
    Total Downloaded
    0
    If you want to be kind to your inverter I suggest you keep it out of the full sun, preferably on the cool side of your house. Less heat should allow it to work harder without risk.

  6. #6
    Join Date
    Aug 2006
    Location
    WA
    Posts
    13,786
    Total Downloaded
    0
    Thanks guys.

    Quote Originally Posted by bee utey View Post
    If you want to be kind to your inverter I suggest you keep it out of the full sun, preferably on the cool side of your house. Less heat should allow it to work harder without risk.
    The inverter is well shaded and only gets about 30 mins of sun in the morning.

    Unfortunately come February I am sure there will be a few 45 degree days.