    Fuel Cooler - Leaking

    Hi there,


    About 1000km ago I replaced the seals for my fuel cooler as it was leaking quite badly when cold. I used genuine vitron (something like that - a brown/pink) seals for the job. I replaced the original clips with clips supplied in the kit I purchased.

    However, it still is leaking a few drops here and there, more that I would really like.


    Any suggestions?


    Thank you kindly good folk!

  2. #2
    Join Date
    Dec 2016
    Location
    New Lambton, NSW
    Posts
    698
    Total Downloaded
    0
    Now many seals did you use?
    You can use two, makes the ends sit in the tube a little straighter and worked a treat on mine!

  3. #3
    Tombie Guest
    Hope you put them in greased and cleaned the mating surfaces...

  4. #4
    Join Date
    Sep 2017
    Location
    Australia
    Posts
    39
    Total Downloaded
    0
    I only used one per end as that is what the kit came with and that is what came out of the unit.

    And absolutely! Cleaned both surfaces with metho and then wiped clean with water. Greased using some KY jelly as mentioned in an advice forum.

    Hence why I am at a loss.

  5. #5
    Join Date
    Jan 2015
    Location
    Brisbane, QLD
    Posts
    137
    Total Downloaded
    0
    You can get new seals from your local bearing/seal shop. BS225 if memory serves me correctly. Think they are about $5 each. Maybe pull the new ones and grab some back ups in case they were damaged during install.
    .............
    Cheers, Josh

  6. #6
    Join Date
    May 2010
    Location
    brighton, brisbane
    Posts
    33,853
    Total Downloaded
    0
    I’m pretty sure the dinosaurs died out when they stopped gathering food and started having meetings to discuss gathering food

    A bookshop is one of the only pieces of evidence we have that people are still thinking

  7. #7
    Join Date
    Dec 2015
    Location
    Perth
    Posts
    60
    Total Downloaded
    0
    i'd recommend changing the o-ring if you haven't already.

    one thing i've done that has worked great is to find a t-hose clamp the same diameter as the fuel cooler and tighten that over the o-ring/fuel cooler.
    that fix has worked for the last 2 years and is still going strong today!
    2000 D2 TD5: Tunit Chipped, EGR Delete, 2" lift, 265s, TJM bullbar, full length roof rack

  8. #8
    Join Date
    Sep 2017
    Location
    Australia
    Posts
    39
    Total Downloaded
    0
    Thanks to everyone for the help.

    A follow up.

    Added another two O rings to the cooler and all is good. No leaks and going strong.