So Im a bit over half way through repair in just one day, have replaced the condenser and got the old pump out.
Im posting all my photos and notes in this thread: (coming soon)
I have some questions about oil, I will call local AC guy when open next to discuss and likely get some more oil.
I drained the old pump and only got 40ml oil (though some was spilt, maybe 5-10ml) but it seems plenty as likely leaked with gas.
There are metal dust in the oil from pump, but no oil traces seem to be exiting the old condenser, so hopefully no metal parts, pump installation manual says if metal in oil replace whole system...
I will flush the line between pump and condenser and inspect tomorrow.
Installation manual with pump says not to add oil to direct to pump, only else where.
The pump comes with oil, manual says 1.4 fl (41ml) oz for condenser replacement.
Manual says total system capacity 4.5 fl oz (133ml)  , maybe I should check how much is in the pump ?