My TDV6 2010 H4 HSE with rear air con also stopped working. It does have a clutch on the front. Its a hybrid compressor with clutch AND variable stroke, with the control valve at the rear of the compressor.
The compressor was spinning with air con on, but no cold air. Pressure test & no gas has leaked.
Service manual states clutch is safety measure if compressor seizes.
There is a service bulletin LTB00693NAS1 regarding this.
I had my system de-gassed, valve replaced with new (disassembled old valve & ill post picks soonish), refrigerant oil replaced (to reduce re-contamination) leak tested & re-gassed. So far so good, but was $900 later.
				
			 
			
		 
			
				
			
			
				2011 RRS HSE 3.0, Blacked out, Straightline exhaust system. 
2010 D4 HSE 3.0, Autocode ECU, Traxide, Redarc EBC, Simoco SRM 9000 UHF.
			
			
		 
	
Bookmarks