    I’m over on Stradbroke Island and the R7 compressor relay has failed. Swapped with the R9 heated windscreen relay. Compressor runs again. Any problems using R9 relay in R7position.

    Another big thumbs-up to the GAP diagnostic tool. Read fault. Googled fault code. Took me to DISCO3.CO.UK. Check relay. Problem solved in 10 mins.
    MY08 TDV6 D3 Zermatt Silver, B.A.S ECU Remap, ARB Bar, 12K Kingone Winch, 2x100Ah LiFePo4 Auxiliary Power, Safari Snorkel, Baja Rack Roof Rack, Brown Davis Aux. Tank, RWC, Front Runner Rear Ladder, Drifta Drawers, Doran TPMS, LLAMS, GAP IID BT.

  2. #2
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,886
    Total Downloaded
    0
    Same or larger amperage relay, it will be fine.

    Slightly smaller, it should also be fine until you get home and replace it.

  3. #3
    Join Date
    Apr 2012
    Location
    Whyalla, SA
    Posts
    7,545
    Total Downloaded
    0
    I’d recommend checking the compressor and servicing it when you get back. The relay failing is likely due to increased current draw from the compressor.

  4. #4
    Join Date
    May 2014
    Location
    Point Cook, VIC
    Posts
    2,472
    Total Downloaded
    0
    If I recall correctly (without going out to car to check), R9 has the same amp rating as R7 and so becomes your spare for the air compressor.

  5. #5
    Join Date
    Jul 2016
    Location
    Blackstone
    Posts
    469
    Total Downloaded
    0
    Thanks everybody.

    For future Reference.

    Fault code was: C1A27-14 Compressor circuit - General electrical failure - circuit short to ground or open.
    MY08 TDV6 D3 Zermatt Silver, B.A.S ECU Remap, ARB Bar, 12K Kingone Winch, 2x100Ah LiFePo4 Auxiliary Power, Safari Snorkel, Baja Rack Roof Rack, Brown Davis Aux. Tank, RWC, Front Runner Rear Ladder, Drifta Drawers, Doran TPMS, LLAMS, GAP IID BT.

  6. #6
    Join Date
    Sep 2014
    Location
    Baldivis WA
    Posts
    2,293
    Total Downloaded
    0
    If the relay failed then the fuse has not done its job to prevent over current in the circuit. But easy fix by the sounds of it. Yes, check the compressor as the only reason it can overload if it cannot move enough air, so dessicant and filter change required,check the piston seal whilst youve got the compressor out.

  7. #7
    Join Date
    May 2014
    Location
    Point Cook, VIC
    Posts
    2,472
    Total Downloaded
    0

    Compressor Relay

    Quote Originally Posted by Tombie View Post
    I’d recommend checking the compressor and servicing it when you get back. The relay failing is likely due to increased current draw from the compressor.
    Quote Originally Posted by Eric SDV6SE View Post
    If the relay failed then the fuse has not done its job to prevent over current in the circuit. But easy fix by the sounds of it. Yes, check the compressor as the only reason it can overload if it cannot move enough air, so dessicant and filter change required,check the piston seal whilst youve got the compressor out.
    Good pick up re this being an early warning sign of a problem with the compressor.

    It is a 60amp relay on a 60amp circuit - but does work very hard and must be operating close to its limit. The contacts end up welding together - hence the fault to earth as I believe the relay forms the earth circuit for the compressor.

    I upgraded mine to a 70amp relay - so could end up blowing a fuse instead.

  8. #8
    Join Date
    Oct 2012
    Location
    Perth
    Posts
    2,700
    Total Downloaded
    0
    Quote Originally Posted by Eric SDV6SE View Post
    If the relay failed then the fuse has not done its job to prevent over current in the circuit. But easy fix by the sounds of it. Yes, check the compressor as the only reason it can overload if it cannot move enough air, so dessicant and filter change required,check the piston seal whilst youve got the compressor out.
    That’s how mine went blowing the fuse and replaced both main fuse and relay. The unit carried on again for months without repeat only giving fault for slow to fill so a worn older compressor runs longer stressing the already old relay and fuse. That’s why new relays are provided with new compressors I imagine.

    Carry a spare fuse in your glovebox or kit I recommend.

    This is a helpful video I did not find till after I did a “full” compressor rebuild and reinstalled it.

    Electric Motor servicing Oem Hitachi Air Suspension Compressor - YouTube

Tags for this Thread

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!