Drier desiccant starting to break down possibly, no dash messages or error codes ?
 Master
					
					
						Subscriber
					
					
						Master
					
					
						SubscriberRecently I changed all struts and all worked well at this stage. Just noticed now at starting the car my compressor runs for a few seconds, stops, then runs a few seconds again etc, etc and after while settles down. it's a D4 MY 2016 with 175K. This is a new issue, what could be the problem? Compressor or ride height sensors or other? Car levels correctly.
Rod
D4 MY16 5 seat TDV6 - LLAMS, Custom Drawers, OL Bar, Toyo Open Country, GOE Rims, Lithium DBS, eDiff, OA Long Range Tank, GAP Tool, Tracklander rack, Mitch Hitch, TPMS & Safari Snorkel
Drier desiccant starting to break down possibly, no dash messages or error codes ?
MY08 TDV6 SE D3- permagrin ooh yeah
2004 Jayco Freedom tin tent
1998 Triumph Daytona T595
1974 VW Kombi bus
1958 Holden FC special sedan
 Master
					
					
						Subscriber
					
					
						Master
					
					
						Subscriber Super Moderator
					
					
						Super ModeratorThis is for a late D3, but all the info I've seen indicates the D4 is similar but maybe with slightly different pressures :
If you have no leaks and don't drop height it should run once every start*, and twice every couple of starts* (2-3 in my experience).
* Where a "start" is after the vehicle being stopped and idle for some indeterminate amount of time I've not been able to accurately pin down (>5 mins and less than an hour).
After months of observation the algorithm "appears" to work like this.
Start car.
Pressurise gallery from reservoir to measure pressure (open reservoir valve, wait until pressure stabilises and close reservoir valve). Note if pressure is above ~16.(5-7) bar absolute.
Vent gallery to ~2bar.
Start compressor and wait until gallery > ~10bar. Stop compressor
Vent gallery to ~2bar.
If initial pressure measurement was < 16.(5-7) bar then :
Start compressor
Open reservoir valve and wait until gallery > 17.7 bar absolute
Stop compressor
Close reservoir valve
Vent gallery to ~2bar.
2 or 3 pressure tests is enough to drop the reservoir below the 16.x threshold and make it pump up. It runs every start and pumps the gallery up > 10 bar as a compressor test.
If I run into the shops, generally it doesn't re-do the test on a warm start.
 Master
					
					
						Subscriber
					
					
						Master
					
					
						SubscriberRod
D4 MY16 5 seat TDV6 - LLAMS, Custom Drawers, OL Bar, Toyo Open Country, GOE Rims, Lithium DBS, eDiff, OA Long Range Tank, GAP Tool, Tracklander rack, Mitch Hitch, TPMS & Safari Snorkel
I have a MY 07 Disco 3 with Hitachi compressor and it does the same thing on start up. Exhausting then running the compressor, then exhausting and running the compressor. I never noticed it until I changed my compressor and removed the sound deadening in the compressor housing. I thought it was a fault with the compressor. Seems like a crazy function to drop the air and run the compressor on every start up all that needless work the compressor performs.