If the gap is sideways - i.e. towards and away from the body, the alignment technique is the bend the bolts that attach the door top to the bottom. If the problem is vertical, it means either the door hinges need adjusting - there is some movement in the bulkhead hinge attachments - or there is a problem with body alignment, possibly due to accident damage or poor assembly.