Page 2 of 2 FirstFirst 12
Results 11 to 14 of 14

Thread: Using Nanocom Evolution to monitor manifold pressure kpa and MAF sensor kg/hr

  1. #11
    Join Date
    Feb 2011
    Location
    Hobart, Tasmania, Australia
    Posts
    3,828
    Total Downloaded
    0
    Eight Run:

    Seem to have had a slight step backwards:

    AF: 642.5

    TP: 221

    EDIT:

    9th run:

    AF: 613.7

    TP: 220.1

    I'm starting to think that close enough is good enough - I'm going to just adjust the AF slightly and be done (the vehicle is driving perfectly, good power levels and EGT so should be fine). I could spend all night making minor adjustments otherwise, and then seasons, day temperature and humidity and what not might even effect it a bit.

  2. #12
    Join Date
    Feb 2011
    Location
    Hobart, Tasmania, Australia
    Posts
    3,828
    Total Downloaded
    0
    Quote Originally Posted by OffTrack View Post
    I think the EVO samples more frequently when it is just displaying data. I'm not 100% on that, but it might be worth double checking using the peak reading button if you have just been going off the recordings.
    I have read that when recording it records once every second.

    What is the peak reading button? Is that one of the three little graph picture buttons down the bottom? I assume the peak reading button might be the one of the graph going up high? How does this function work?

  3. #13
    Join Date
    Jan 1970
    Location
    Avoca Beach
    Posts
    14,152
    Total Downloaded
    0
    You press the button and the Instrument display shows peak reading for 1or 2 seconds in the same session.
    Regards Philip A

  4. #14
    Join Date
    Feb 2011
    Location
    Brunswick, Victoria
    Posts
    3,778
    Total Downloaded
    0
    Quote Originally Posted by twr7cx View Post
    I have read that when recording it records once every second.

    What is the peak reading button? Is that one of the three little graph picture buttons down the bottom? I assume the peak reading button might be the one of the graph going up high? How does this function work?
    Yes the three graph buttons are the one you need. When you are viewing inputs the Evo stores the highest and lowest values that have occured since you opened the module. The graph button with the X clears the stored values, so you can reset between runs without exit the module. When I tried accessing peak values while recording the values wouldn't display, so it seems you can't do both at the same time.

    cheers
    Paul