Not to me
bridging the signal from one sensor to both inputs and leaving one sensor unplugged will keep the compressor running untill the SLABS gets the target height input so if you start with that with even level from the bumps both bags will get the air for the same time cos the height inputs for both sides are the same being from one sensor... corroborated with what i said before about voltage drop the level might be different than the normal cos one sensor's signal divided in two can be different than on one single circuit for the reasons i explained... better dont bother with this theory and fix the wiring issue somehow then calibrate it and IMO it will be good