Originally Posted by
winaje
I have checked the voltage at the wires to this sensor, and it's 4.95v with the ignition turned on, and it does not change while cranking. According to the info, the voltage applied varies between 0 and 12v.
Does anyone know of a way to test this PCV? It's just a solenoid, can I safely apply 12v directly to it and see if the car starts?
Thanks again.
The PCV signal will be pwm at around 40% duty cycle for your meter to show around 5V, with the 40% duty cycle partly closing the valve to provide some rail pressure as the valve is open when without power. Applying 12V to obtain full pump pressure should not be required and may subject the rail and injectors to excessive pressure.
You can check the solenoid's coil for continuity but if you can hear the valve click (which it probably wont without full 12V applied) when the ignition is first switched on then its working.
MY21.5 L405 D350 Vogue SE with 19s. Produce LLAMS for LR/RR, Jeep GC/Dodge Ram
VK2HFG and APRS W1 digi, RTK base station using LoRa