Page 3 of 5 FirstFirst 12345 LastLast
Results 21 to 30 of 46

Thread: Intermittent not starting

  1. #21
    Join Date
    Mar 2008
    Location
    Coogee, South of Fremantle, WA
    Posts
    1,550
    Total Downloaded
    0
    Quote Originally Posted by RoverHse View Post
    Thanks Wayne. Just installed the new fuse box and new relays. Turned on the ignition, went through all the "set window" beeps, tried to start, and..... ABS FAULT! And won't even spin.

    Back to the forums I go.
    I would be putting the original fusebox back and try again, at least double check all the plugs snapped home OK . If you want to just try my gems fusebox to confirm its not the new box faulty I still have it here..

  2. #22
    Join Date
    Feb 2013
    Location
    Gosford, NSW, Australia
    Posts
    2,556
    Total Downloaded
    0
    Hi

    This definitely sounds like an electrical problem, have you checked all the earth connections?

    Perhaps it is worth running the electrical checks outlined here?


    Sticky: Electrical Troubleshooting Updated 2010

    Regards
    Steve

  3. #23
    Join Date
    Jul 2010
    Location
    Mullaloo, Perth, WA
    Posts
    98
    Total Downloaded
    0

    Intermittent starting ....... Continued

    Swopped back the old box as suggested by Wayne.... Starter kicked over and no more ABS fault. So thought I would sit down and make sure that the relays are all in the correct place, only to find that when compared relay by relay the fuse box layout was different!!!! Further investigations has shown that it is a '99- model YQE 103410, while I needed AMR 3375 or AMR 6405.

    The difference is that the the box supplied has engine relays at RL2 and RL10, while mine has ABS at RL2 and RL10 is a blank, which will explain the ABS fault and no engine kick over.

    Wayne, what does your one look like. I may take you up on your offer to get me back on the road while waiting for the swop out of my new box.
    Attached Images Attached Images

  4. #24
    Join Date
    Mar 2008
    Location
    Coogee, South of Fremantle, WA
    Posts
    1,550
    Total Downloaded
    0
    We are in a reversed situation I ordered a Thor and they sent Gems, you the opposite. If mine was not used I would suggest a swap.

  5. #25
    Join Date
    Jul 2010
    Location
    Mullaloo, Perth, WA
    Posts
    98
    Total Downloaded
    0
    Hi Wayne, I've sent you a PM.

  6. #26
    Join Date
    Jul 2010
    Location
    Mullaloo, Perth, WA
    Posts
    98
    Total Downloaded
    0
    Ok, so my new correct fuse box arrives.in it goes, turn the sky and starts.... Yay. Then all of a sudden the starter motor kicks in. I turn off the ignition, but the starter keeps going until I disconnect the battery. Now the minute I reconnect the battery the starter gets going without the ignition on??????

    BECM serviced, new crank sensor and new fuse box, and still no go.

    Anybody have ideas..

  7. #27
    Join Date
    Feb 2010
    Location
    Townsville, QLD
    Posts
    2,581
    Total Downloaded
    0
    Sticky solenoid? Bad relay? Ignition short?

    I'm only poking, I have no idea.

    Good luck!

  8. #28
    Join Date
    Jul 2010
    Location
    Mullaloo, Perth, WA
    Posts
    98
    Total Downloaded
    0
    I switched out the relay...no luck. Have not had any starter motor issues before either!!!!!

  9. #29
    Join Date
    Aug 2007
    Location
    Brisbane
    Posts
    3,234
    Total Downloaded
    0
    I'd follow Keithy's suggestion about the solenoid. If you remove the key from the ignition so that the ignition switch is completely out of consideration. Remove the relevant relays. Now touch the disconnected lead to the battery terminal, does the starter fire up? If so, then the solenoid is somehow being energised, or, it's failing to release.

    Also, carefully check how you have reconnected the new fuse box... are you sure all the heavy duty cables are properly routed/connected?
    MY99 RR P38 HSE 4.6 (Thor) gone (to Tasmania)
    2020 Subaru Impreza S ('SWMBO's Express' )
    2023 Ineos Grenadier Trialmaster (diesel)

  10. #30
    Join Date
    Jul 2010
    Location
    Mullaloo, Perth, WA
    Posts
    98
    Total Downloaded
    0
    Thanks Hoges, I'm going to put a test light on the activation wire to the solenoid tonight to check if it is a power supply issue, if not then pretty sure it will be the solenoid.

    I numbered the power cables to the fuse box when I removed them, and double checked the photo of the plugs on the bottom.

Page 3 of 5 FirstFirst 12345 LastLast

Bookmarks

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Search AULRO.com ONLY!
Search All the Web!