It'll work but with 2 problems (well 4 but 3 are nearly the same)
1. The return fuel from the injectors is the fuel thats used to keep the injectors internals cooled if you just circulate it in a loop it'll get hotter.
2. The fuel system will be slightly more problematic to bleed
3. Any air getting in will make the engine more prone to starving out.
4. if you get an injector passing combustion gasses into the line you'll starve out.
Depending on where in QLD you are feel free to come on over and you can check out Fozz's plumbing. I've also got some left over fittings that you can mess around with.
My solution for multi tanks on a series diesel has always been to run one tank as per normal and then pump fuel from other tanks into that one via the breathers