Make sure the tank's cap is completely tightened cos if it isn't there will not be the required 1,4 bar in the system and it will overflow... did you lift the tank above the top hose when you filled the system?
undo partially the bleed screw, and rev it above 1500(as the mechanical bypass valve of the stat to open) and keep it so untill no bubbles are coming out there, maybe there's an airlock if it wasn't properly bled
are you sure the pump is working ok? you must have serious flow at the bleed hole with engine running even at idle
by the way, using a gauge is more reliable as nanocom doesnt actually read the temperature but the coolant temp sensor's input to ECM, and the temp sensor might be fubar'd
Discovery Td5 (2000), manual, tuned