    On my 1999 TD5 110 I used measurements of 380mm from left hand wheelarch and 530mm from rear door to centre of pump,use a hole saw to check position.Put a plate between pump and floor to prevent damage to fuel lines and cut the hole with a jig saw.My tank was a long range tank from LRA,but the pump location is the same as original.