Originally Posted by
Vern
When mike did his at my place, I'm fairly sure he drilled and tapped a half inch hole in the centre
If thats what he did then I'm surprised that he ever got it to drain well enough as the shaft blocks that hole completely once the cover is fitted (apart from a few thou clearance for it to run in.
I know I had discussion with Mike as to what size he was using, but it could have been over the phone or PM if its not in his thread.
Watch out for the internal bore of the fittings you use Judo - as some have very thick walls and small bores. Drill them out if necessary.
I think bee utey's suggestion of fitting a pipe end using silver solder or pressing would be the most practical to get the largest bore in the limited space available.
Other option is the breather cover as someone said earlier. I think Rovercare took that option with his 120 build. I think that's where my provent drain goes and IIRC there was reasonable thickness to do it.
Steve
1985 County - Isuzu 4bd1 with HX30W turbo, LT95, 255/85-16 KM2's
1988 120 with rust and potential
1999 300tdi 130 single cab - "stock as bro"
2003 D2a Td5 - the boss's daily drive