Page 2 of 2 FirstFirst 12
Results 11 to 13 of 13

Thread: wont turn over at all TD5 auto

  1. #11
    Join Date
    Sep 2009
    Location
    Central Vic
    Posts
    683
    Total Downloaded
    0
    Quote Originally Posted by V8Ian View Post
    It could be in the barrel, how much does your bunch of keys weigh?
    not much, ignition key plus 1 house key...
    89 RRC
    92 RRC Sherwood

  2. #12
    Join Date
    Sep 2009
    Location
    Central Vic
    Posts
    683
    Total Downloaded
    0
    bit of an update....
    No problems at all since turning off the immobilizer...

    Give it a bit more time and see how it goes. thankfully i live rural...
    89 RRC
    92 RRC Sherwood

  3. #13
    Join Date
    Sep 2009
    Location
    Central Vic
    Posts
    683
    Total Downloaded
    0

    Solved

    TD5 engine bay fusebox (960 x 540).jpg

    ok, still had this problem even with immobilizer off.
    the wire from the starter solenoid is red/brown, i traced this back to the fuse block in the engine bay,(easier than it sounds) the red/brown wire plugs into a male fitting on the fuse block, the wire obviously has a female plug on it, this connection was loose, so simply squashing the female plug a little and refitting seems to have fixed the problem.
    Last edited by roverv8; 27th December 2017 at 06:02 AM. Reason: add pic
    89 RRC
    92 RRC Sherwood