  1. #11
    Join Date
    Jan 1970
    Location
    Down the road from Sydney
    Posts
    14,702
    Total Downloaded
    0
    Quote Originally Posted by Grappler View Post
    The wire under the ground between the fence post needs to be insulated.
    Rural supply outlets have this type of insulated wire. Its good to put it inside some irrigation pipe to protect it.
    The tape would soon short out to the ground if buried, even if inside a pipe

    So I could just get a small amount of this wire run it under ground through some pipe and attach it to the tape on either side when it comes out the ground?

    am I reading you right.


    MichaelI dont want the tape in the gate areas at all....thats the purpose of my question....

    and I have a solar unit got it for Chrisy...but its more of a mobile unit the plan is to tape all the paddocks but move the unit to which ever paddock is being used at the time or I could do a run of one tape....as the unit will do up to 7klm Im worried that one brake in it though will be hard to track down on such a long line
    Our Land Rover does not leak oil! it just marks its territory.......




  2. #12
    Join Date
    Nov 2012
    Location
    ACT
    Posts
    44
    Total Downloaded
    0
    Worth investing in a testing tool,simply touch the hot wire and it says if its live,makes testing/fault finding very quick.
    Andrew[/QUOTE]


    My wife is happy to be the testing tool - go figure.

  3. #13
    Join Date
    Jan 2009
    Location
    On the road around Australia
    Posts
    900
    Total Downloaded
    0
    Quote Originally Posted by dullbird View Post
    So I could just get a small aamouth fo this wire run it under ground through some pipe and attach it to the tape on either side when it comes out the ground?

    am I reading you right.
    Yep, in a nutshell. Doesn't have to be some specific cable either - insulated electrical cable works just fine.

    As someone mentioned, pick up one of those screwdriver-type fence testers if you're worried about tracking down breaks in the fence. Makes tracking down frays or breaks an easy task.

  4. #14
    Join Date
    Feb 2004
    Location
    Williams West Aust
    Posts
    20,998
    Total Downloaded
    0
    In winter time,a wet blade of grass works well.
    Did see a workmate climb over an electric fence,they had switched it off at the gate thinking that because the switch was off it was all off.
    NOPE it was still hot up to the gate,got him in the nuts,was a very strong system too,on a Bull Stud
    We had to laugh,he rekoned they ached for over a week
    Andrew
    DISCOVERY IS TO BE DISOWNED
    Midlife Crisis.Im going to get stuck into mine early and ENJOY it.
    Snow White MY14 TDV6 D4
    Alotta Fagina MY14 CAT 12M Motor Grader
    2003 Stacer 525 Sea Master Sport
    I made the 1 millionth AULRO post

  5. #15
    Join Date
    Jan 1970
    Location
    Down the road from Sydney
    Posts
    14,702
    Total Downloaded
    0
    wow its good to know that you don't have to complete a circuit I'm guessing it doesn't matter if you do complete it though..

    how does it work does the current flow backwards and forwards (AC?)...or does it only become live once the animal touches it effectively creating a circuit?

    its even better to know that you can just piggy back off the line in different directions...

    is there a good way of joining tape or do you literally just tie it in a knot one to the other

    As you can tell I dont have a lot of experience with electric stuff hahahah
    Our Land Rover does not leak oil! it just marks its territory.......




  6. #16
    Join Date
    Feb 2004
    Location
    Williams West Aust
    Posts
    20,998
    Total Downloaded
    0
    The circuit is between the hot wire and the ground,hence the need for an earth spike.Some systems do run a seperate eart wire,usually for big naughty animals and weak fences.
    Havent had much to do with the tape,we did try it on a spring flush paddock with lambs to selectively graze,wasnt much good,we simply tied knots in the stuff.
    Google Gallagher,they have some good gear and should have user guides.

    Andrew
    DISCOVERY IS TO BE DISOWNED
    Midlife Crisis.Im going to get stuck into mine early and ENJOY it.
    Snow White MY14 TDV6 D4
    Alotta Fagina MY14 CAT 12M Motor Grader
    2003 Stacer 525 Sea Master Sport
    I made the 1 millionth AULRO post

  7. #17
    Join Date
    May 2009
    Location
    West Gippsland - Victoria
    Posts
    2,907
    Total Downloaded
    0
    Quote Originally Posted by dullbird View Post
    So I could just get a small aamouth fo this wire run it under ground through some pipe and attach it to the tape on either side when it comes out the ground?

    am I reading you right............................................. ..
    Exactly!

    You can't feed the tape or string directly through the pipe as it is not insulated and would break down electrically to ground even though encased in pipe.

    On a slightly different tangent, whilst you are designing and building your electric fence system, DON'T (sorry for the caps) have closed loops of electric fencing in your design. By this I mean having the electric fence connected in a continuous circle around your boundary or in your paddocks. This is gauranteed to provide all sorts of electric fence interference for you and/or your neighbours telephone, TV, radio etc. Always leave a gap, either at a gate or at a corner post.

    From someone who has spent a large ammount of time chasing electric fence interference in the telephone network I can tell you that you, your neighbours and your local Telstra staff will be most grateful.

    Deano

  8. #18
    Join Date
    Jan 2009
    Location
    On the road around Australia
    Posts
    900
    Total Downloaded
    0
    The electric fence is basically a step-up transformer - it converts the power in a 12 volt battery to 10,000 to 20,000 volts, but at a very low amperage. Much the same as a stun gun. High enough voltage to shock, but current so low that it can never kill.

    The fence pulses at 20,000v quite happily, much the same as the power lines over your head do, without frying everything in the vicinity. However, when an animal touches the fence, it creates a circuit, and thus a potential difference between the fence (20,000v) and the ground it's standing on (0v), and thus the animal gets a shock. That potential difference has to exist though - if you went out to the fence and stood on a sheet of styrofoam, then grabbed the fence, you wouldn't get shocked - no circuit between the fence and ground.

  9. #19
    Join Date
    Jan 1970
    Location
    Down the road from Sydney
    Posts
    14,702
    Total Downloaded
    0
    so I would probably be better to run a single tape around the whole lot then (all paddocks and just run it at as single wire and not close any of them off to complete the circuit..

    thank you all for your help


    Thanks Mike thats what I wondered thanks for confirming......so the click you hear from the fence is simply and electric pulse running down the wire
    Our Land Rover does not leak oil! it just marks its territory.......




  10. #20
    Join Date
    Jan 2009
    Location
    On the road around Australia
    Posts
    900
    Total Downloaded
    0
    you can run the tape in any direction you want, and no, you don't need to complete a ring circuit, or anything like that. If it's just one paddock, with one gate, you can start the tape at one gatepost, run it round the paddock, and terminate it at the other gatepost. Just hook up the electric fence anywhere around the field, and it will work fine.