    Think I've cracked it now. A couple of the new ball valve outlets were leaking. Got it down to just a tiny leak now. Will see how it is in the morning. Might have to replace that ball valve.

    Fingers crossed.

  3. #33
    Join Date
    Feb 2013
    Location
    Gosford, NSW, Australia
    Posts
    2,556
    Total Downloaded
    0
    Quote Originally Posted by davidsonsm View Post
    Think I've cracked it now. A couple of the new ball valve outlets were leaking. Got it down to just a tiny leak now. Will see how it is in the morning. Might have to replace that ball valve.

    Fingers crossed.
    Mate

    Good news, I hope you finally have it sorted!

    Steve

  4. #34
    Join Date
    Feb 2012
    Location
    Carnegie
    Posts
    1,226
    Total Downloaded
    0
    Scraped the 4x ball valves. Nice idea to ease swap over to the manual inflation system, but it does introduce more potential leakage points. Might try again in the future with some solenoid valves. For now, I'm just happy to be riding on my auto eas.

  5. #35
    Join Date
    May 2010
    Location
    Mindarie, Western Australia
    Posts
    1,141
    Total Downloaded
    0
    Quote Originally Posted by davidsonsm View Post
    Scraped the 4x ball valves. Nice idea to ease swap over to the manual inflation system, but it does introduce more potential leakage points. Might try again in the future with some solenoid valves. For now, I'm just happy to be riding on my auto eas.
    Well done! Enjoy riding on air

    Gary

  6. #36
    Join Date
    Feb 2012
    Location
    Carnegie
    Posts
    1,226
    Total Downloaded
    0
    Still have a problem. The compressor is new and gets to 145psi. But its fighting against a leak. So it takes quite a while. The car stays at height. But with a pressure gauge on the air tank line, the pressure soon drops and restarts the compressor. I can hear the leak, but can't find it. It sounds like its coming from the drier.

    Will have to investigate further tomorrow.

  7. #37
    Join Date
    Feb 2012
    Location
    Carnegie
    Posts
    1,226
    Total Downloaded
    0
    Worked out what was happening. In a static situation, the tank air was leaking quite rapidly. Turned out it was leaking through the exhaust in a pulsing fashion. I doubled checked the diaphragm valve and the exhaust valve, but nothing obvious there. Hence the need to whip the valve block out again and check those pesky NRV's.

    I'd put the best one I had in position no. 1. The one in position no. 3 wasn't up to the task and was causing the leak. One of the spare valve blocks I had ($200 delivered out of USA) had 2 nearly new looking NRV's and one slightly less good. Out the six, I picked the best three. It seems to be working.

    Incredible. Such a small part that represents a real Achilles heel to these cars. As they get older, good NRV's are going to get sparser.

    What are we to do about it? Buy a new valve block?

    As stated above, I also have another spare 2nd hand valve block - I'll pick the best bits out of the two spares I have, and maintain an "as new" valve block for years to come. What a bloody palaver this has been.

  8. #38
    Join Date
    May 2010
    Location
    Mindarie, Western Australia
    Posts
    1,141
    Total Downloaded
    0
    Quote Originally Posted by davidsonsm View Post
    Worked out what was happening. In a static situation, the tank air was leaking quite rapidly. Turned out it was leaking through the exhaust in a pulsing fashion. I doubled checked the diaphragm valve and the exhaust valve, but nothing obvious there. Hence the need to whip the valve block out again and check those pesky NRV's.

    I'd put the best one I had in position no. 1. The one in position no. 3 wasn't up to the task and was causing the leak. One of the spare valve blocks I had ($200 delivered out of USA) had 2 nearly new looking NRV's and one slightly less good. Out the six, I picked the best three. It seems to be working.

    Incredible. Such a small part that represents a real Achilles heel to these cars. As they get older, good NRV's are going to get sparser.

    What are we to do about it? Buy a new valve block?

    As stated above, I also have another spare 2nd hand valve block - I'll pick the best bits out of the two spares I have, and maintain an "as new" valve block for years to come. What a bloody palaver this has been.
    Well done for the perseverance! It probably feels like all your Christmases have come at once

    Gary

  9. #39
    Join Date
    Sep 2008
    Location
    Poland (I kid you not)
    Posts
    376
    Total Downloaded
    0
    Re spare parts, I've been thinking the same thing. Wonder if the eas can be swapped out for another air system?

  10. #40
    Join Date
    Jan 2012
    Location
    Bendigo
    Posts
    1,643
    Total Downloaded
    0
    Subarus had an eas system around the same era....

    Sent from my GT-I9305T using AULRO mobile app