    Des, you'd have barely finished your apprenticeship when that was commissioned.
    If you don't like trucks, stop buying stuff.
    http://www.aulro.com/afvb/signaturepics/sigpic20865_1.gif

  2. #1082
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,886
    Total Downloaded
    0
    Quote Originally Posted by rick130 View Post
    Not too many Star/Delta starts anymore.
    Either part winding start or VSD
    Yes you are correct, part winding start.

    4Bee,its usually just the fill that needs replacing, gaskets on the inspection panels, sprays if they are broken, floats,corroded strainer, and a few other things.Fan motor bearings, shaft bearings if they have them.Blades,fan scrolls, baffle plates, etc.
    These towers are 20yrs old, but I recon a good refurb and they will keep going, fibreglass shell.

    Not me making the decision to replace them, I have said before, the Govt love to spend/waste money at times, but other times they wont spend a cent.They would be better off getting the BMS sorted, and recoup the power savings.We have chiller plant wasting power,Chilled water valves jammed open and reheats running, etc,etc.VAV's not working properly as well.

  3. #1083
    Join Date
    Jan 1970
    Location
    Adelaide Hills. South Australia
    Posts
    13,349
    Total Downloaded
    0
    Quote Originally Posted by V8Ian View Post
    Des, you'd have barely finished your apprenticeship when that was commissioned.

    Thanks for that Ian.


    Who you think got the job of charging the Ammonia System in the confined space?


    Come in Sucker & I did. Of course I was aware of being part of Adelaide's Colonial History.

  4. #1084
    Join Date
    Dec 2007
    Location
    Back down the hill.
    Posts
    29,769
    Total Downloaded
    0
    Quote Originally Posted by 4bee View Post
    Thanks for that Ian.


    Who you think got the job of charging the Ammonia System in the confined space?


    Come in Sucker & I did. Of course I was aware of being part of Adelaide's Colonial History.
    I'll bet you were Adelaide's very own Wild Colonial Boy.
    If you don't like trucks, stop buying stuff.
    http://www.aulro.com/afvb/signaturepics/sigpic20865_1.gif

  5. #1085
    Join Date
    Jan 1970
    Location
    Adelaide Hills. South Australia
    Posts
    13,349
    Total Downloaded
    0
    Quote Originally Posted by V8Ian View Post
    I'll bet you were Adelaide's very own Wild Colonial Boy.

    Not true, but if you like to keep thinking that I can live with it.


    I can use a bit of Street Cred.

  6. #1086
    Join Date
    Dec 2007
    Location
    Back down the hill.
    Posts
    29,769
    Total Downloaded
    0
    Better than street cred, Des; you've got AULRO cred.
    If you don't like trucks, stop buying stuff.
    http://www.aulro.com/afvb/signaturepics/sigpic20865_1.gif

  7. #1087
    Join Date
    Jan 1970
    Location
    Adelaide Hills. South Australia
    Posts
    13,349
    Total Downloaded
    0
    Quote Originally Posted by V8Ian View Post
    Better than street cred, Des; you've got AULRO cred.


    HeeeYaaah. I've made the big time so does that mean I can swear on here now? Oh **** 'ang on a mo.


  8. #1088
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,886
    Total Downloaded
    0
    Mate of mine did his time at W&S,they were a huge Mechanical Services and Refrigeration company in their day.

    Did a lot of Ammonia Refrigeration,as well as some huge AC, DX jobs.
    Duhig library at QLd Uni comes to mind, four 8 cyl open drive Tranes,with evaporative condensers.Two tandem systems.
    Probably all gone, been replaced with chillers.

    Talking about Star Delta starts,many years ago,i saw a tech start a York chiller, with the contactors wired incorrectly.
    Brand new job,Beaufort Hotel in the city, we did the install of the mech services.I think its called something else these days.
    From memory, we just replaced the contacts in the contacters,after it was wired correctly.

    All the refrigeration units for the kitchen and restaurants had shell and tube condensers cooled by the water from the chilled water system.Hyatt Coolum was the same.

  9. #1089
    Join Date
    Jan 1970
    Location
    NSW far north coast
    Posts
    17,285
    Total Downloaded
    0
    You may recall I replaced a Carpark CO exhaust fan and attenuator at the beginning of the year.
    I wanted to use a VSD but we just replaced the Star/Delta of the old system.

    The store manager rang and said the fan wasn't running after the sparkies had supposedly commissioned it.

    I walked in, the main breaker was tripped so I rang the office and the head electrical engineer assured me it had been running so I reset the breaker.
    It started, then bang.

    I checked the connections on the roof, it was all wired correctly so I dry ran the contactors. It'd been so long since I'd worked on S/D I had to Google the connections One for the fridgies
    The supplied bridge from Schneider crossed the phases when it went to Delta.
    Visually you couldn't see it, you had to meter it as the bridge was all plastic encased but no way it had been running.
    I think he just walked away as it was a $25k job and he didn't want to be responsible, but it took a fridgey to fix it. One for the fridgiesOne for the fridgies

  10. #1090
    Join Date
    Jan 1970
    Location
    Adelaide Hills. South Australia
    Posts
    13,349
    Total Downloaded
    0
    Quote Originally Posted by scarry View Post
    Mate of mine did his time at W&S,they were a huge Mechanical Services and Refrigeration company in their day.

    Did a lot of Ammonia Refrigeration,as well as some huge AC, DX jobs.
    Duhig library at QLd Uni comes to mind, four 8 cyl open drive Tranes,with evaporative condensers.Two tandem systems.
    Probably all gone, been replaced with chillers.

    Talking about Star Delta starts,many years ago,i saw a tech start a York chiller, with the contactors wired incorrectly.
    Brand new job,Beaufort Hotel in the city, we did the install of the mech services.I think its called something else these days.
    From memory, we just replaced the contacts in the contacters,after it was wired correctly.

    All the refrigeration units for the kitchen and restaurants had shell and tube condensers cooled by the water from the chilled water system.Hyatt Coolum was the same.




    W&S.

    Forty years ago I'd never heard of them until a Sales Engineer where I worked at the time said he was going with them as the SA Rep.

    Sad in a way that the companies that we knew so well & in most cases respected have all disappeared. Kelvy was another. POPE? Was never a manufacturer of quality gear imho. Why? simple really, the panels on their units were meant for Battleship Armour. Heavy as old **** & badly fitting.

    Maybe it was summat we said.