    Quote Originally Posted by scarry View Post
    Des in his day,New set of work clothes on


    It can't be Des, that fellow's wearing shorts.
    If you don't like trucks, stop buying stuff.
    http://www.aulro.com/afvb/signaturepics/sigpic20865_1.gif

  2. #1122
    Join Date
    Jan 1970
    Location
    Adelaide Hills. South Australia
    Posts
    13,349
    Total Downloaded
    0
    Quote Originally Posted by scarry View Post
    Des in his day,New set of work clothes on



    But overdressed as usual.

  3. #1123
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,886
    Total Downloaded
    0
    Interesting,from Mitsubishi Electric,refering to their AC units, and interconnecting cables.


  4. #1124
    Join Date
    Jan 1970
    Location
    NSW far north coast
    Posts
    17,285
    Total Downloaded
    0
    Quote Originally Posted by scarry View Post
    Interesting,from Mitsubishi Electric,refering to their AC units, and interconnecting cables.

    I asked a sparkie a little while back and he uses 1.5mm2 interconnect and reckons it's ok as it can be argued it's...Damn, too many One for the fridgies tonight One for the fridgies

  5. #1125
    Join Date
    May 2006
    Location
    Woolgoolga
    Posts
    7,870
    Total Downloaded
    0
    Quote Originally Posted by scarry View Post
    Interesting,from Mitsubishi Electric,refering to their AC units, and interconnecting cables.

    I came across this years ago when doing a few mitsi units, the aircon guy wanted me to run either a twin or sdi (can't remember) as part of the interconnects due to inductance issues, not that any issues ever arose.

  6. #1126
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,886
    Total Downloaded
    0
    Quote Originally Posted by rick130 View Post
    I asked a sparkie a little while back and he uses 1.5mm2 interconnect and reckons it's ok as it can be argued it's...Damn, too many One for the fridgies tonight One for the fridgies
    Yep,i think I ran into the same bloke as well,a while while ago, said this and that and its fine....,on a 20A circuit.

    Dumb Fridgies,WTF would they know

    I am glad you are enjoying the drinks

  7. #1127
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,886
    Total Downloaded
    0
    Quote Originally Posted by Vern View Post
    I came across this years ago when doing a few mitsi units, the aircon guy wanted me to run either a twin or sdi (can't remember) as part of the interconnects due to inductance issues, not that any issues ever arose.
    Actually,i will admit, we generally use orange 4 core circ,but have never ever had an issue.Always 2.5mm square.

    But yes, to be 100% correct, must be Twin and SDI,as the SDI must be used for the comms cable.Thats if there are three interconnects plus earth.

    I am surprised our sparky hasn't pulled us up on it as he is right onto things.

    Had some relays in a mechanical services switchboard recently switching both 24V and 240 V,and tracking across causing all sorts of issues.Blew two relays out of the bases.

    Maybe not against the rules, but not good.

  8. #1128
    Join Date
    Jan 1970
    Location
    NSW far north coast
    Posts
    17,285
    Total Downloaded
    0
    Quote Originally Posted by Vern View Post
    I came across this years ago when doing a few mitsi units, the aircon guy wanted me to run either a twin or sdi (can't remember) as part of the interconnects due to inductance issues, not that any issues ever arose.
    Yep never had a problem with any splitty I've installed using 4 core but i used shielded cable on the controls of wired remotes for cassettes in commercial installations I installed and the install boys use it for City Multis at the current place.

  9. #1129
    Join Date
    Jan 1970
    Location
    NSW far north coast
    Posts
    17,285
    Total Downloaded
    0
    Quote Originally Posted by scarry View Post
    Yep,i think I ran into the same bloke as well,a while while ago, said this and that and its fine....,on a 20A circuit.

    Dumb Fridgies,WTF would they know

    I am glad you are enjoying the drinks
    Cheers Paul.
    Making up for being on call over New Year's One for the fridgies

  10. #1130
    Join Date
    Apr 2008
    Location
    Brisbane,some of the time.
    Posts
    13,886
    Total Downloaded
    0
    We had 7 calls the last hot weekend, now its cooled down, none so far.

    Although it doesnt worry me,i have resigned from the on call stuff

    Although my phone does still ring,3.28AM one day last week,and 4.48am one day the week before.

    The 4.48am one was the refrigerant alarm going off in the chiller plant room, the chiller guys went and said it says R404a,so it must be one of the cold room units, that are also in the plant room.So one of the boys gets there, and he can hear the leak on the York chiller, runs on R134a.Cold/frz units are fine.